Pump power calculator

Hydraulic, shaft and electrical power of a pump from flow and head or pressure, with efficiencies, the next standard motor size and the energy cost.

Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person. Report a problem

Introduction

A pump lifts a flow of liquid against a head. The power that ends up in the liquid, the hydraulic power, is density × gravity × flow × head. The pump wastes part of the shaft power it receives, and the motor wastes part of the electricity, so the power drawn from the grid is noticeably more. Pumping 50 m³/h of water against 30 m puts 4.08 kW into the water but draws about 6.5 kW of electricity.

This calculator gives the hydraulic, shaft and electrical input power of a pump from the flow and either the head or the pressure rise, the next standard motor size with a margin, and the yearly energy and cost. It is for engineers and technicians selecting pumps and motors, and checking running costs.

Formulas

Power at each stage:

P_h = ρ g Q H = Q Δp
P_shaft = P_h / η_pump
P_in = P_shaft / η_motor

US units (brake horsepower):

BHP = Q[gpm] × H[ft] × SG / (3 960 × η_pump)
  • ρ — liquid density; g = 9.81 m/s²; Q — flow; H — total head
  • Δp — pressure rise, with H = Δp / (ρ g)
  • η_pump, η_motor — pump and motor efficiencies at the duty point

Assumptions and limitations

  • The head is the total dynamic head: static lift, friction and fitting losses, and any pressure difference between the tanks. The total dynamic head calculator works it out.
  • Pump efficiency must be read from the pump curve at the duty point. Small pumps reach 40 to 60 %, large ones 75 to 85 %. Running far from the best efficiency point wastes energy and wears the pump.
  • Viscous liquids reduce the pump's efficiency and head. Correct them with the Hydraulic Institute viscosity method before using this page.
  • The motor size uses IEC rated outputs in kW. North American NEMA motors are rated in hp: 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20 hp and so on.

Worked example

A centrifugal pump delivers 50 m³/h of water (998 kg/m³) against a total head of 30 m. Its efficiency is 70 % and the motor's 90 %. What power is needed?

  1. Flow: 50 / 3 600 = 0.01389 m³/s.
  2. Hydraulic power: 998 × 9.81 × 0.01389 × 30 = 4.08 kW.
  3. Shaft power: 4.08 / 0.70 = 5.83 kW.
  4. Electrical input: 5.83 / 0.90 = 6.47 kW.
  5. Motor with 10 % margin: 5.83 × 1.1 = 6.41 kW, so a 7.5 kW motor.

Running 4 000 hours a year, the pump uses about 26 MWh of electricity.

FAQ

How do I calculate pump power?

Multiply density, gravity, flow and head for the hydraulic power, then divide by the pump efficiency for the shaft power. For water, kW = m³/h × m / 367 / efficiency.

What is brake horsepower?

The power the pump needs at its shaft. In US units it is gpm × feet × specific gravity / (3 960 × efficiency).

What size motor do I need for my pump?

At least the shaft power at the worst operating point, plus a margin of 10 to 20 %. Then choose the next standard motor rating.

How do I convert pressure to head?

Divide the pressure by density × gravity. For water, 1 bar is 10.2 m and 1 psi is 2.31 ft.

What is a typical pump efficiency?

40 to 60 % for small domestic and circulator pumps, 70 to 85 % for large process and water-supply pumps at their best efficiency point.

How can I cut a pump's energy use?

Run near the best efficiency point, reduce pipe losses, and use a variable-speed drive where the flow varies: power falls with the cube of speed.

Related calculators

Cite this calculator

Papandreou, C. (2026). Pump power calculator. Engineering Bible. https://engineeringbible.com/fluids/pump-power/

Embed this calculator on your site

Copy this HTML into your page. The calculator stays free to use and links back here.

By Christos Papandreou. How the numbers are checked.