Introduction
To choose a pump you need two numbers: the flow, and the head the pump must add at that flow, the total dynamic head (TDH). The head has three parts: lifting the liquid from one level to another, any pressure difference between the vessels, and the losses to friction in the pipe and its fittings. The lift is fixed; the losses grow with the square of the flow, which gives the rising system curve that the pump curve must cross.
This calculator adds up the three parts for a single pipe size. It gives the velocity, Reynolds number and friction factor, each head component, the total dynamic head and the hydraulic power, and the system curve as a simple equation. It is for engineers and contractors selecting centrifugal pumps for water and other liquids.
Formulas
Total dynamic head:
TDH = (z_d − z_s) + (p_d − p_s) / (ρ g) + (f L / D + ΣK) × v² / (2g)
Friction factor (Darcy–Weisbach with Colebrook):
Re = v D / ν
1/√f = −2 log10( ε/(3.7 D) + 2.51/(Re √f) ), f = 64/Re if laminar
System curve:
H(Q) ≈ H_static + C Q², C = (f L/D + ΣK) / (2 g A²)
- z_d − z_s — static lift from the suction surface to the discharge surface
- p_d − p_s — difference in gauge pressure between the two vessels
- f — Darcy friction factor; L — pipe length; D — inside diameter; ΣK — fittings
- ν — kinematic viscosity; ε — pipe roughness
Assumptions and limitations
- The liquid moves between two vessels whose surfaces are the reference points, so the velocity there is zero and the exit loss belongs in ΣK.
- The pipe is one size throughout. For a system with several sizes, calculate each section's losses separately and add them.
- The Colebrook equation covers turbulent flow; between Re 2 300 and 4 000 the flow is transitional and the friction factor uncertain.
- The system curve assumes the friction factor stays close to its design value as the flow changes, which is accurate in fully turbulent flow.
Worked example
A pump moves 20 m³/h of water at 20 °C from a sump to a tank 15 m higher, through 100 m of 3 in steel pipe (77.9 mm bore) with fittings totalling K = 8. What head must the pump deliver?
- Velocity: (20 / 3 600) / (π × 0.0779² / 4) = 1.166 m/s; velocity head 0.0693 m.
- Reynolds number: 1.166 × 0.0779 / 1.004 × 10⁻⁶ = 90 440, turbulent.
- Friction factor from Colebrook with ε = 0.046 mm: f = 0.0210.
- Pipe friction: 0.0210 × 100 / 0.0779 × 0.0693 = 1.86 m. Fittings: 8 × 0.0693 = 0.55 m.
- Total dynamic head: 15 + 1.86 + 0.55 = 17.42 m.
Choose a pump whose curve passes through 20 m³/h at about 17.5 m, near its best efficiency point.
FAQ
What is total dynamic head?
The total head a pump adds to the liquid: the static lift, the pressure difference between the vessels, and all friction and fitting losses, in metres or feet of the liquid pumped.
How do I calculate TDH?
Add the vertical lift, the pressure difference converted to head, and the friction and fitting losses. Friction is f L / D × v² / 2g and fittings are ΣK × v² / 2g.
What is the difference between static head and dynamic head?
Static head is the lift and pressure difference, which exist even at zero flow. Dynamic head adds the losses that appear when liquid flows.
What is a system curve?
The head the system needs at each flow. The pump operates where its own curve crosses the system curve.
Does suction lift add to TDH?
Yes. If the pump lifts from a sump below it, the static lift is measured from the sump surface to the discharge surface, which includes the suction lift. Check NPSH too.
Why does head matter more than pressure for pumps?
A pump adds the same head whatever the liquid's density, but the pressure it produces scales with density. Pump curves are therefore drawn in head.
Related calculators
- Pump power — the power for the flow and head.
- Minor losses — add up K for the fittings.
- Pipe flow and pressure drop — friction in pipes in detail.
- Pump NPSH — checking the suction side.