General engineering formulas
The formulas behind the 4 general calculators, on one page you can print or save as a PDF. Each block lists its variables and standard; the heading opens the calculator, with its assumptions and a worked example.
Engineering unit converter
Every unit has a factor to the base unit of its quantity, and temperature units also have an offset:
base = (value + offset) × factor
value = base / factor − offset
converted = fromBase(toBase(value, from), to)
Key exact definitions used (base units SI):
| Unit | Definition |
|---|---|
| nautical mile | 1852 m |
| knot | 1 nmi/h = 0.514444 m/s |
| inch, foot, yard, mile | 25.4 mm, 0.3048 m, 0.9144 m, 1609.344 m |
| pound, long ton, short ton | 0.45359237 kg, 2240 lb = 1016.0469 kg, 2000 lb = 907.18474 kg |
| tonne | 1000 kg |
| pound-force, kilogram-force | 4.4482216 N, 9.80665 N |
| psi, bar, atm, mmHg | 6894.757 Pa, 10⁵ Pa, 101 325 Pa, 133.3224 Pa |
| horsepower, metric horsepower (PS) | 550 ft·lbf/s = 745.69987 W, 75 kgf·m/s = 735.49875 W |
| Btu (IT), calorie (thermochemical), kWh, toe | 1055.05585 J, 4.184 J, 3.6 MJ, 41.868 GJ |
| US gallon, imperial gallon, oil barrel | 3.785411784 L, 4.54609 L, 158.987295 L |
| °F to K | (°F + 459.67) × 5/9; °C to K: °C + 273.15 |
Quantities covered: length, area, volume, mass, time, speed, angle, force, pressure and stress, torque, power, energy, volume flow, mass flow, density, temperature, temperature difference, specific fuel consumption, rotational speed, ratio, price per mass, cost per distance, mass per distance, TPC, MCTC, mass moment, kinematic and dynamic viscosity, heat transfer coefficient, thermal conductivity, specific heat, second moment of area, section modulus, distributed load, voltage, current, resistance, resistivity, resistance per length, acceleration, frequency, fouling resistance.
Measurement uncertainty (GUM)
u(xᵢ) = value / divisor: normal 1, expanded k = 2 → 2, rectangular √3, triangular √6, U-shaped √2, Type A √n
u_c(y) = √ Σ (cᵢ u(xᵢ))² (uncorrelated inputs)
ν_eff = u_c⁴ / Σ ( (cᵢ u(xᵢ))⁴ / νᵢ ) Welch–Satterthwaite
k = t_p(⌊ν_eff⌋) (95.45 % → 2.00 for large ν), U = k u_c
report U with two significant digits and y to the same decimal place
Quick statistics of a series
x̄ = Σx/n, s = √(Σ(x − x̄)²/(n − 1)), SE = s/√n
CI = x̄ ± t(1 − α/2, n − 1) SE
Q1, Q3: linear interpolation between order statistics (type 7), IQR = Q3 − Q1
G1 = √(n(n−1))/(n−2) · m₃/m₂^1.5, G2 = [(n+1) g₂ + 6](n−1)/((n−2)(n−3)), g₂ = m₄/m₂² − 3
trend: y = a + b x (least squares), t = b/SE(b), p = 2[1 − F_t(|t|, n − 2)]
Tukey: x < Q1 − 1.5 IQR or x > Q3 + 1.5 IQR
Chauvenet: n · P(|Z| > |x − x̄|/s) < 0.5
Grubbs: G = max|x − x̄|/s > ((n − 1)/√n) √(t²/(n − 2 + t²)), t = t(1 − α/(2n), n − 2)
Reliability and redundancy
Unit availability: A = MTBF / (MTBF + MTTR)
Mission reliability: R(t) = e^(−t / MTBF)
k-out-of-n block: P = Σ_{j=k..n} C(n, j) p^j (1 − p)^(n−j)
System (series): Π P_block
Median ranks: F_i = (i − 0.3)/(n + 0.4)
Weibull line: ln t = ln η + (1/β) ln(−ln(1 − F))
B10 life and mean: η (−ln 0.9)^(1/β), η Γ(1 + 1/β)
Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person.