Pipe roughness table (absolute roughness)

The absolute roughness ε is the average height of the bumps on a pipe’s inner wall. Divided by the diameter it gives the relative roughness ε/D, which with the Reynolds number sets the friction factor on the Moody chart. Commercial steel is 0.045 mm, so a 100 mm steel pipe has ε/D = 0.00045. The table lists the usual design values.

Free to reuse under CC BY 4.0 with a link to this page. Each table downloads as a CSV file.

To compute any value directly: Pipe flow and pressure drop

Absolute roughness of new pipes

Materialε (mm)ε (in)ε (ft)
Drawn tubing, copper, brass0.00150.0000590.0000049
PVC / plastic0.00150.0000590.0000049
Stainless steel0.0150.000590.000049
Commercial steel, wrought iron0.0450.00180.00015
Galvanized iron0.150.00590.00049
Cast iron0.260.0100.00085
Concrete, average1.00.0390.0033
Riveted steel3.00.120.0098

Download this table as CSV

How the table was made

Values from Moody (1944) as tabulated in White, Fluid Mechanics, Table 6.1; stainless steel from Crane TP-410. Roughness grows with age, scale and corrosion: an old steel main can be several times rougher than a new one.

FAQ

What roughness should I use for PVC pipe?
0.0015 mm. Plastic pipe is hydraulically smooth for most flows.

What roughness does Hazen–Williams use?
None: it uses the C factor instead, about 150 for plastic and 120 to 140 for new steel. The Darcy–Weisbach method with ε is valid for any fluid; Hazen–Williams only for water.

  • Pipe flow and pressure drop: Velocity, Reynolds number, Darcy friction factor (Colebrook, Swamee–Jain) and pressure drop for a straight pipe with fittings.
  • Hazen–Williams head loss calculator: Hazen–Williams friction loss of water in a pressure pipe, or the flow or pipe diameter for an allowed loss, with velocity, pressure drop and C-factors.
  • Reynolds number and flow regime: Reynolds number for a pipe, a non-circular duct, a flat plate or any length, from velocity or flow, with the regime: laminar, transitional or turbulent.
  • Minor losses calculator (pipe fittings and valves): Head and pressure loss through elbows, tees, valves, entrances and exits by the Crane K method, with total K and the equivalent pipe length.

Sources

  • Moody, L. F. (1944), Friction factors for pipe flow, Trans. ASME 66, 671–684.
  • White, F. M., Fluid Mechanics, Table 6.1.
  • Crane Co., Technical Paper No. 410, Flow of Fluids.

Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person. Report a problem