Absolute roughness of new pipes
| Material | ε (mm) | ε (in) | ε (ft) |
|---|---|---|---|
| Drawn tubing, copper, brass | 0.0015 | 0.000059 | 0.0000049 |
| PVC / plastic | 0.0015 | 0.000059 | 0.0000049 |
| Stainless steel | 0.015 | 0.00059 | 0.000049 |
| Commercial steel, wrought iron | 0.045 | 0.0018 | 0.00015 |
| Galvanized iron | 0.15 | 0.0059 | 0.00049 |
| Cast iron | 0.26 | 0.010 | 0.00085 |
| Concrete, average | 1.0 | 0.039 | 0.0033 |
| Riveted steel | 3.0 | 0.12 | 0.0098 |
How the table was made
Values from Moody (1944) as tabulated in White, Fluid Mechanics, Table 6.1; stainless steel from Crane TP-410. Roughness grows with age, scale and corrosion: an old steel main can be several times rougher than a new one.
FAQ
What roughness should I use for PVC pipe?
0.0015 mm. Plastic pipe is hydraulically smooth for most flows.
What roughness does Hazen–Williams use?
None: it uses the C factor instead, about 150 for plastic and 120 to 140 for new steel. The Darcy–Weisbach method with ε is valid for any fluid; Hazen–Williams only for water.
Calculators that use this table
- Pipe flow and pressure drop: Velocity, Reynolds number, Darcy friction factor (Colebrook, Swamee–Jain) and pressure drop for a straight pipe with fittings.
- Hazen–Williams head loss calculator: Hazen–Williams friction loss of water in a pressure pipe, or the flow or pipe diameter for an allowed loss, with velocity, pressure drop and C-factors.
- Reynolds number and flow regime: Reynolds number for a pipe, a non-circular duct, a flat plate or any length, from velocity or flow, with the regime: laminar, transitional or turbulent.
- Minor losses calculator (pipe fittings and valves): Head and pressure loss through elbows, tees, valves, entrances and exits by the Crane K method, with total K and the equivalent pipe length.
Sources
- Moody, L. F. (1944), Friction factors for pipe flow, Trans. ASME 66, 671–684.
- White, F. M., Fluid Mechanics, Table 6.1.
- Crane Co., Technical Paper No. 410, Flow of Fluids.