Heat transfer and thermodynamics practice problems

10 multiple-choice problems in the style of the FE and PE engineering exams. Pick an answer to check it, then open the worked solution. Every answer is recomputed by the thermal calculator that solves it, and the solution opens that calculator with the problem's numbers filled in.

  1. Heat delivered by a heat pump at half the Carnot COP

    A water-to-water heat pump takes heat from a brine loop at 5 °C and delivers it to a heating circuit at 45 °C. Its real COP is 50 % of the Carnot COP between these temperatures. The compressor draws 3 kW of electrical power. How much heat does the heat pump deliver to the heating circuit?

    Show the answer and worked solution

    Answer: A, 11.9 kW

    1. Carnot heating COP: T_h / (T_h − T_c) = 318.15 / (318.15 − 278.15) = 7.95.
    2. Real COP: 0.5 × 7.95 = 3.98.
    3. Heat delivered: Q_h = COP × W = 3.98 × 3 = 11.9 kW.
    4. The traps: 1.7 kW uses °C instead of kelvin (45 / 40), 10.4 kW uses the refrigerating COP T_c / (T_h − T_c), and 23.9 kW forgets the 50 % fraction of Carnot.
  2. Area of a counterflow oil cooler by LMTD

    In a counterflow oil cooler, 1.5 kg/s of oil (specific heat 2100 J/(kg·K)) is cooled from 130 °C to 60 °C by water that is heated from 20 °C to 50 °C. The overall heat transfer coefficient is 320 W/(m²·K) and fouling is neglected. What heat transfer area is required?

    Show the answer and worked solution

    Answer: C, 11.9 m²

    1. Duty: Q = ṁ c_p ΔT = 1.5 × 2100 × (130 − 60) = 220.5 kW.
    2. Counterflow terminal differences: ΔT₁ = 130 − 50 = 80 K, ΔT₂ = 60 − 20 = 40 K. LMTD = (80 − 40) / ln(80 / 40) = 57.7 K.
    3. Area: A = Q / (U × LMTD) = 220 500 / (320 × 57.7) = 11.9 m².
    4. The traps: 11.5 m² uses the arithmetic mean difference (60 K), 16.5 m² uses the parallel-flow differences (110 K and 10 K), and 6.3 m² uses the inlet temperature difference of 110 K.
  3. Cold outlet temperature by the effectiveness–NTU method

    A counterflow water-to-water heat exchanger has U = 1100 W/(m²·K) and an area of 6 m². Hot water enters at 90 °C at 1.2 kg/s (c_p 4190 J/(kg·K)). Cold water enters at 15 °C at 0.8 kg/s (c_p 4180 J/(kg·K)). Using the effectiveness–NTU method, what is the cold water outlet temperature?

    Show the answer and worked solution

    Answer: D, 70.2 °C

    1. Capacity rates: C_h = 1.2 × 4190 = 5028 W/K, C_c = 0.8 × 4180 = 3344 W/K, so C_min = 3344 W/K (cold side) and C_r = 0.665.
    2. NTU = U A / C_min = 1100 × 6 / 3344 = 1.974.
    3. Counterflow: ε = (1 − e^(−NTU(1 − C_r))) / (1 − C_r e^(−NTU(1 − C_r))) = 0.737.
    4. The cold stream is C_min: T_c,out = 15 + ε (90 − 15) = 15 + 0.737 × 75 = 70.2 °C.
    5. The traps: 58.4 °C uses the parallel-flow ε, 61.7 °C divides UA by C_max instead of C_min, and 51.7 °C divides the duty by the hot capacity rate.
  4. Radiation loss from a hot oven casing

    The outer casing of an industrial oven has 4 m² of surface at 150 °C with an emissivity of 0.85. It stands in a large hall whose walls are at 25 °C. Take σ = 5.67 × 10⁻⁸ W/(m²·K⁴). What is the net heat loss from the casing by radiation alone?

    Show the answer and worked solution

    Answer: B, 4.66 kW

    1. Net radiation to large surroundings: Q = ε σ A (T_s⁴ − T_sur⁴), with temperatures in kelvin.
    2. Q = 0.85 × 5.67 × 10⁻⁸ × 4 × (423.15⁴ − 298.15⁴) = 4 658 W = 4.66 kW.
    3. The traps: 6.18 kW forgets the radiation coming back from the surroundings, 5.48 kW forgets the emissivity, and 0.10 kW puts the temperatures in °C.
  5. Mass of air in a compressed-air receiver

    A 0.5 m³ compressed-air receiver is charged to 7.0 bar gauge. The local atmospheric pressure is 101.325 kPa and the air in the receiver is at 30 °C. Treat air as an ideal gas with a molar mass of 28.96 g/mol and R = 8.314 J/(mol·K). What mass of air does the receiver hold?

    Show the answer and worked solution

    Answer: D, 4.60 kg

    1. Absolute pressure: p = 700 000 + 101 325 = 801 325 Pa. Temperature: T = 30 + 273.15 = 303.15 K.
    2. Amount: n = p V / (R T) = 801 325 × 0.5 / (8.314 × 303.15) = 159.0 mol.
    3. Mass: m = n M = 159.0 × 0.02896 = 4.60 kg.
    4. The traps: 4.02 kg uses the gauge pressure, 46.53 kg uses the temperature in °C, and 5.11 kg uses 273.15 K (standard temperature) instead of the actual 30 °C.
  6. Quench time of a steel ball by lumped capacitance

    A steel ball 20 mm in diameter (density 7850 kg/m³, specific heat 460 J/(kg·K), conductivity 45 W/(m·K)) leaves a furnace at 850 °C and is quenched in oil at 40 °C. The heat transfer coefficient is 120 W/(m²·K). Using the lumped capacitance model, how long does the ball take to cool to 100 °C?

    Show the answer and worked solution

    Answer: A, 261 s

    1. For a sphere V / A = d / 6 = 0.00333 m. Biot number h (V / A) / k = 120 × 0.00333 / 45 = 0.009 < 0.1, so lumped capacitance holds.
    2. Time constant: τ = ρ c (V / A) / h = 7850 × 460 × 0.00333 / 120 = 100.3 s.
    3. Time: t = τ ln((T₀ − T∞) / (T − T∞)) = 100.3 × ln(810 / 60) = 261 s.
    4. The traps: 783 s takes V / A as the radius, 215 s uses the ratio of the temperatures themselves (850 / 100) instead of the differences from the oil, and 392 s uses V / A = d / 4, the long-cylinder value.
  7. Heat loss per metre of an insulated steam line

    A steam line has an outside diameter of 114.3 mm and a 6 mm steel wall (k = 50 W/(m·K)). Steam inside is at 180 °C with an inside film coefficient of 1000 W/(m²·K). The pipe has 50 mm of mineral wool insulation with k = 0.04 W/(m·K). Ambient air is at 20 °C and the outside coefficient is 10 W/(m²·K). What is the heat loss per metre of pipe?

    Show the answer and worked solution

    Answer: C, 60.3 W/m

    1. Resistances per metre in series: inside film 1 / (h_i π D_i) = 0.0031, steel wall ln(D_o / D_i) / (2π k) = 0.0004, insulation ln(214.3 / 114.3) / (2π × 0.04) = 2.501, outside film 1 / (h_o π × 0.2143) = 0.1485 K·m/W.
    2. Total R = 2.653 K·m/W.
    3. Heat loss: q = ΔT / R = (180 − 20) / 2.653 = 60.3 W/m.
    4. The traps: 86.2 W/m treats the insulation as a flat slab (k ΔT / t) over the outer surface, 63.9 W/m leaves out the outside film resistance, and 46.0 W/m uses the flat slab over the pipe surface.
  8. Time to heat a batch of thermal oil

    A 500 kg batch of thermal oil with a specific heat of 2.1 kJ/(kg·K) is heated from 20 °C to 180 °C by a 30 kW electric heater. Only 90 % of the heater output reaches the oil; the rest is lost. Neglect any other losses. How long does the heat-up take?

    Show the answer and worked solution

    Answer: B, 1.73 h

    1. Heat to the oil: Q = m c ΔT = 500 × 2100 × (180 − 20) = 168 MJ.
    2. Useful heating rate: 0.9 × 30 = 27 kW.
    3. Time: t = Q / (η P) = 168 000 000 / 27 000 = 6 222 s = 1.73 h.
    4. The traps: 1.56 h forgets the 90 % efficiency, 1.40 h multiplies the time by the efficiency instead of dividing, and 1.94 h uses the final temperature of 180 °C as the temperature rise.
  9. Specific enthalpy of wet steam from the steam tables

    A boiler delivers wet steam at 10 bar absolute with a dryness fraction of 0.90. Using the IAPWS-IF97 steam tables for saturated water and steam at this pressure, what is the specific enthalpy of the wet steam?

    Show the answer and worked solution

    Answer: D, 2 580 kJ/kg

    1. At 10 bar absolute: T_sat = 179.9 °C, h_f = 762.7 kJ/kg, h_fg = 2014.4 kJ/kg, h_g = 2777.1 kJ/kg.
    2. Wet steam: h = h_f + x h_fg = 762.7 + 0.90 × 2014.4 = 2 576 kJ/kg, or 2 580 kJ/kg to three figures.
    3. The traps: 2 500 kJ/kg multiplies h_g by x (as if the liquid carried no enthalpy), 2 780 kJ/kg ignores the wetness, and 964 kJ/kg uses (1 − x) in place of x.
  10. Anchor force on a fully restrained hot steel pipe

    A 60 m straight run of carbon steel pipe, 168.3 mm outside diameter and 7.1 mm wall, is anchored at both ends with no expansion loop. It is installed at 15 °C and operates at 95 °C. Take α = 12 × 10⁻⁶ /K and E = 200 GPa. What axial force does each anchor carry?

    Show the answer and worked solution

    Answer: A, 690 kN

    1. Full restraint: σ = E α ΔT = 200 × 10⁹ × 12 × 10⁻⁶ × (95 − 15) = 192 MPa (compressive). The length does not enter.
    2. Metal area: A = π (D_o² − D_i²) / 4 = π × (0.1683² − 0.1541²) / 4 = 3 596 mm².
    3. Anchor force: F = σ A = 192 × 10⁶ × 0.003596 = 690 kN.
    4. The traps: 820 kN uses the operating temperature of 95 °C as ΔT, 4 271 kN uses the full circle of the outside diameter as the area, and 3 581 kN uses the circle of the bore.

Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person.