Introduction
Newton's law of cooling says that a body loses heat in proportion to its temperature difference from the surroundings. The difference therefore falls exponentially with a time constant τ. A cup of coffee that drops from 90 to 70 °C in 10 minutes in a 20 °C room has τ = 29.7 minutes, and it is at 45.5 °C after half an hour.
This calculator gives the temperature after a time, or the time to reach a temperature, for cooling or heating. The time constant can be entered, calculated from the body's size, density, specific heat and heat transfer coefficient, or found from two temperature readings. It checks the Biot number, which tells you whether the simple law applies. It is for engineers, students and anyone timing a quench, a sensor response or a cooling product.
ρ, V, c, m — density, volume, specific heat and mass of the body
h — heat transfer coefficient; A — surface area; k — conductivity of the body
L_c — characteristic length: D/6 for a sphere
Assumptions and limitations
The body has one uniform temperature at any moment. This holds when the Biot number is below 0.1. Above that, the surface cools faster than the core and the result is only an estimate.
The surrounding temperature, the heat transfer coefficient and the properties stay constant. In practice h falls as the body approaches T∞, and radiation adds to it at high temperature.
The same law covers heating. A cold body warms towards T∞ with the same time constant.
With two readings, the first is the start. Both must lie on the same side of T∞, and the second must be closer to it.
Worked example
Incropera Example 5.1 is a thermocouple bead, a sphere of 0.706 mm diameter. Its properties are ρ = 8 500 kg/m³, c = 400 J/(kg·K) and k = 20 W/(m·K). It sits in a gas stream at 200 °C with h = 400 W/(m²·K). How long does it take to read 199 °C, starting from 25 °C?
Characteristic length: L_c = D / 6 = 0.706 / 6 = 0.118 mm.
Biot number: 400 × 0.000118 / 20 = 0.00235, far below 0.1, so the lumped model holds.
Time constant: τ = ρ c D / (6 h) = 8 500 × 400 × 0.000706 / 2 400 = 1.00 s.
Time to 199 °C: 1.00 × ln[(25 − 200) / (199 − 200)] = ln 175 = 5.2 s.
The book gives the same 5.2 s, about five time constants.
The worked example, drawn by the same code as the live drawing above.
FAQ
What is Newton's law of cooling?
The rate of heat loss is proportional to the temperature difference between the body and its surroundings. The difference then decays as e^(−t/τ).
How do I find the cooling constant from measurements?
Take two readings and the surrounding temperature. τ = t / ln[(T0 − T∞)/(T1 − T∞)], and the cooling constant k is 1/τ.
What is the time constant?
The time for the difference to fall to 36.8 % of its starting value. After five time constants less than 1 % remains.
What is the Biot number?
The ratio of the resistance to conduction inside the body to the resistance to convection at its surface. Below 0.1 the inside stays nearly uniform, and Newton's law applies to the whole body.
What heat transfer coefficient should I use?
Incropera's Table 1.1 gives 2 to 25 W/(m²·K) for free convection in gases and 25 to 250 for forced convection in gases. Liquids are higher: 50 to 1 000 free and 100 to 20 000 forced.
Does Newton's law work for heating as well?
Yes. A cold drink in a warm room warms towards room temperature with the same exponential curve.
Related calculators
Heat transfer — steady conduction, convection and radiation.
Before every release the calculator must reproduce each case below. The note under each case says where the expected answer comes from: a standard, a textbook, a published table, or a hand calculation shown in full.
Incropera Example 5.1: thermocouple bead 0.706 mm has τ = 1 s, Bi = 2.35 × 10⁻³, and reaches 199 °C from 25 °C in 5.2 sIncropera et al., Fundamentals of Heat and Mass Transfer, 7th ed., Example 5.1 (D, τ and t); Bi = h (D/6)/k by hand
After one time constant 36.8 % of the initial difference remains; the difference halves in τ ln 2Newton's law of cooling T = T∞ + (T0 − T∞) e^(−t/τ) (Incropera eq. 5.6)
Two readings: coffee 90 °C falls to 70 °C in 10 min in a 20 °C room, so τ = 10 / ln(70/50) = 29.7 min and it is 45.5 °C after 30 minτ = t1 / ln[(T0 − T∞)/(T1 − T∞)] (hand calculation)
Geometry and Biot: a 100 mm steel ball (k 50) quenched in water at h = 1 000 has Bi = 0.33 and warns; cylinder V and A by handBi = h (V/A)/k with V/A = D/6 for a sphere; Incropera Section 5.2 criterion Bi < 0.1
Heating works the same way: a 4 °C drink in a 24 °C room with τ = 1 h reaches 14 °C in 41.6 min; heat gained is m c ΔTNewton's law of cooling applied to warming (hand calculation)
Invalid input: a target beyond T∞, a second reading on the wrong side and a zero diameter are rejectedBehaviour check: warnings and rejected inputs
Worked example of the article: the calculator reproduces 1.00 s, 5.2 s, 0.00235 to the digits printedThe worked example on this page, to the digits printed
Assumptions and sources
Assumptions and limits
The body has one uniform temperature at any instant (lumped capacitance). This holds when the Biot number h L_c / k, with L_c = V/A, is below 0.1 (Incropera Section 5.2); above that the surface cools faster than the core and the result is only indicative.
The surrounding temperature T∞, the heat transfer coefficient h and the properties are constant. Radiation can be included in h as a linearised coefficient; for large temperature differences it varies and the curve is no longer a pure exponential.
The same equation covers heating: a body colder than its surroundings approaches T∞ from below with the same time constant.
From two readings, the first is taken as the start (t = 0) and the time constant follows from the ratio of the temperature differences; both readings must lie on the same side of T∞.
A cylinder includes both ends in its surface area; for a long rod or wire whose ends are insulated, use the custom shape.
Sources
F. P. Incropera, D. P. DeWitt, T. L. Bergman & A. S. Lavine, Fundamentals of Heat and Mass Transfer, 7th ed., Sections 5.1–5.2 (lumped capacitance, eqs. 5.6 and 5.10, Biot number criterion) and Example 5.1
Y. A. Çengel & A. J. Ghajar, Heat and Mass Transfer: Fundamentals and Applications, 5th ed., Section 4.1 (lumped system analysis, Bi ≤ 0.1)
Cite this calculator
Papandreou, C. (2026). Newton's law of cooling calculator. Engineering Bible. https://engineeringbible.com/thermal/newtons-cooling/
Embed this calculator on your site
Copy this HTML into your page. The calculator stays free to use and links back here.