Fluid mechanics and pumps practice problems
10 multiple-choice problems in the style of the FE and PE engineering exams. Pick an answer to check it, then open the worked solution. Every answer is recomputed by the fluids and pumps calculator that solves it, and the solution opens that calculator with the problem's numbers filled in.
-
Shaft power of a cooling water pump
A centrifugal pump delivers 50 m³/h of water with a density of 998 kg/m³ against a total head of 30 m. The pump efficiency at this duty is 70 %. What shaft power must the motor supply to the pump?
Show the answer and worked solution
Answer: B, 5.83 kW
- Hydraulic power: P_h = ρ g Q H = 998 × 9.80665 × (50 / 3600) × 30 = 4.08 kW.
- Shaft power: P_shaft = P_h / η_pump = 4.08 / 0.70 = 5.83 kW.
- The traps: 4.08 kW forgets the pump efficiency, 6.47 kW also divides by a 90 % motor efficiency, and 2.86 kW multiplies by the efficiency instead of dividing.
Check every step: Pump power calculator, opened with this problem’s numbers
-
Mean water velocity in a DN 100 pipe
A DN 100 Schedule 40 steel pipe with a bore of 102.3 mm carries 12 L/s of cooling water. What is the mean velocity of the water in the pipe?
Show the answer and worked solution
Answer: C, 1.46 m/s
- Bore area: A = π D² / 4 = π × 0.1023² / 4 = 0.008219 m².
- Velocity: V = Q / A = 0.012 / 0.008219 = 1.46 m/s.
- The traps: 0.37 m/s uses A = π D² (the diameter put in place of the radius), 1.53 m/s uses the nominal 100 mm instead of the actual bore, and 5.84 m/s uses A = π r² / 4 with the radius.
Check every step: Flow rate and pipe velocity, opened with this problem’s numbers
-
Pressure at the throat of a venturi meter
Water with a density of 998 kg/m³ flows horizontally through a venturi meter. The inlet bore is 150 mm and the throat bore is 75 mm. At the inlet the gauge pressure is 250 kPa and the velocity is 1.5 m/s. Neglect losses. What is the gauge pressure at the throat?
Show the answer and worked solution
Answer: A, 233 kPa
- Continuity: V₂ = V₁ (D₁ / D₂)² = 1.5 × (150 / 75)² = 6.0 m/s.
- Bernoulli with z₁ = z₂: p₂ = p₁ − ½ ρ (V₂² − V₁²) = 250 000 − 0.5 × 998 × (36 − 2.25) = 233 159 Pa.
- The throat gauge pressure is 233 kPa.
- The traps: 247 kPa scales the velocity by the diameter ratio instead of its square (V₂ = 3 m/s), 267 kPa adds the dynamic pressure change instead of subtracting it, and 216 kPa drops the ½ in the kinetic term.
Check every step: Bernoulli's equation and venturi, opened with this problem’s numbers
-
Friction head loss in a cement-lined water main
A cement-lined ductile iron water main, 850 m long with a bore of 200 mm, carries 25 L/s. Take a Hazen–Williams coefficient C of 130. Using the SI Hazen–Williams formula, what is the friction head loss over the whole length?
Show the answer and worked solution
Answer: D, 3.02 m
- SI Hazen–Williams: h_f = 10.67 L Q^1.852 / (C^1.852 d^4.8704).
- h_f = 10.67 × 850 × 0.025^1.852 / (130^1.852 × 0.2^4.8704) = 3.02 m.
- The traps: 4.91 m uses C = 100 (old unlined iron), 2.32 m uses C = 150 (plastic pipe), and 0.36 m is the loss per 100 m reported as the loss for the whole main.
Check every step: Hazen–Williams head loss calculator, opened with this problem’s numbers
-
Darcy–Weisbach pressure drop in a steel water line
Water at 20 °C (density 998.2 kg/m³, kinematic viscosity 1.004 mm²/s) flows at 20 L/s through 250 m of straight commercial steel pipe with a bore of 102.3 mm and an absolute roughness of 0.045 mm. Using the Colebrook friction factor, what is the friction pressure drop?
Show the answer and worked solution
Answer: B, 131 kPa
- Velocity: V = Q / (π D² / 4) = 0.02 / 0.008219 = 2.43 m/s; Re = V D / ν = 2.43 × 0.1023 / 1.004 × 10⁻⁶ = 2.48 × 10⁵ (turbulent).
- Relative roughness ε / D = 0.045 / 102.3 = 0.00044; Colebrook gives f = 0.0181.
- Darcy–Weisbach: Δp = f (L / D) ρ V² / 2 = 0.0181 × (250 / 0.1023) × 998.2 × 2.43² / 2 = 131 kPa.
- The traps: 33 kPa uses the Fanning factor (f / 4) in the Darcy formula, 524 kPa uses 4 f with the Darcy factor, and 262 kPa divides the length by the radius instead of the diameter.
Check every step: Pipe flow and pressure drop, opened with this problem’s numbers
-
Total dynamic head to fill a pressurised tank
A pump moves 25 m³/h of water (998.2 kg/m³, kinematic viscosity 1.004 mm²/s) from an open sump to a tank whose liquid level is 18 m higher and whose gas space is held at 1.5 bar gauge. The line is 120 m of steel pipe, bore 77.9 mm, roughness 0.046 mm, with fittings totalling ΣK = 9. Using Colebrook friction, what total dynamic head must the pump deliver?
Show the answer and worked solution
Answer: C, 37.7 m
- Velocity: V = (25 / 3600) / (π × 0.0779² / 4) = 1.457 m/s; Re = 1.13 × 10⁵, Colebrook f = 0.0204.
- Friction head: h_f = f (L / D) V² / 2g = 0.0204 × (120 / 0.0779) × 1.457² / (2 × 9.80665) = 3.40 m. Fittings: ΣK V² / 2g = 9 × 0.1082 = 0.97 m.
- Pressure head: Δp / ρ g = 150 000 / (998.2 × 9.80665) = 15.32 m.
- TDH = 18 + 15.32 + 3.40 + 0.97 = 37.7 m.
- The traps: 22.4 m leaves out the tank pressure, 36.7 m leaves out the fitting losses, and 34.3 m leaves out the pipe friction.
Check every step: Total dynamic head (TDH) calculator, opened with this problem’s numbers
-
Shaft power after a speed reduction (affinity laws)
A circulating pump runs at 1480 rpm, delivering 180 m³/h against 42 m of head and drawing 30 kW at the shaft. A variable-speed drive slows it to 1250 rpm. Assuming the efficiency stays the same, what shaft power does the pump draw at the new speed?
Show the answer and worked solution
Answer: A, 18.1 kW
- Affinity law for power: P₂ = P₁ (N₂ / N₁)³.
- P₂ = 30 × (1250 / 1480)³ = 30 × 0.6025 = 18.1 kW.
- The traps: 21.4 kW uses the square of the speed ratio (the head law), 25.3 kW uses the plain ratio (the flow law), and 49.8 kW inverts the ratio.
Check every step: Pump and fan affinity laws, opened with this problem’s numbers
-
NPSH available for a pump lifting hot water
A pump draws water at 60 °C from an open tank at sea level (101.325 kPa). The vapour pressure is 19.9 kPa absolute and the density 983 kg/m³. The water level is 2.5 m below the impeller centreline and the suction line loses 0.8 m at duty flow. What NPSH is available?
Show the answer and worked solution
Answer: D, 5.15 m
- NPSHa = (p_atm − p_v) / (ρ g) + z_s − h_f, with z_s negative for a suction lift.
- Pressure head: (101 325 − 19 900) / (983 × 9.80665) = 8.45 m.
- NPSHa = 8.45 − 2.5 − 0.8 = 5.15 m.
- The traps: 7.21 m forgets the vapour pressure, 10.15 m adds the suction lift instead of subtracting it, and 5.95 m forgets the suction friction loss.
Check every step: Pump NPSH and suction lift, opened with this problem’s numbers
-
Flow from a smooth-bore washdown nozzle
A smooth-bore nozzle with a 25 mm tip and a discharge coefficient of 0.97 discharges water (density 998 kg/m³) to atmosphere. The pressure at the nozzle inlet is 5 bar gauge. What is the flow in litres per minute?
Show the answer and worked solution
Answer: B, 904 L/min
- Jet velocity: v = √(2 Δp / ρ) = √(2 × 500 000 / 998) = 31.65 m/s.
- Flow: Q = C_d A v = 0.97 × (π × 0.025² / 4) × 31.65 = 0.01507 m³/s = 904 L/min.
- The traps: 932 L/min forgets the discharge coefficient, 639 L/min drops the 2 under the root (v = √(Δp / ρ)), and 3 617 L/min uses A = π d² with the diameter in place of the radius.
Check every step: Nozzle flow calculator (orifice, fire nozzle and K-factor), opened with this problem’s numbers
-
Joukowsky surge from a fast valve closure
Water (density 998 kg/m³, bulk modulus 2.19 GPa) flows at 1.8 m/s in a 600 m steel main with a 250 mm bore and 7 mm wall (E = 207 GPa, expansion joints throughout). A valve at the end closes in 0.5 s, faster than 2L/a. What is the Joukowsky pressure surge?
Show the answer and worked solution
Answer: C, 22.7 bar
- Wave speed in the liquid: √(K / ρ) = √(2.19 × 10⁹ / 998) = 1 481 m/s.
- Korteweg: a = 1 481 / √(1 + (K / E)(D / e)) = 1 481 / √(1 + (2.19 / 207) × (250 / 7)) = 1 262 m/s. Then 2L/a = 0.95 s, so the 0.5 s closure is rapid.
- Joukowsky: Δp = ρ a Δv = 998 × 1 262 × 1.8 = 2.27 MPa = 22.7 bar.
- The traps: 26.6 bar treats the pipe as rigid (a = 1 481 m/s), 43.1 bar applies the slow-closure Michaud formula 2 ρ L Δv / t_c to a rapid closure, and 11.3 bar puts a ½ in front of ρ a Δv.
Check every step: Water hammer (Joukowsky), opened with this problem’s numbers
Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person.