Fluid mechanics and pump formulas
The formulas behind the 19 fluids and pumps calculators, on one page you can print or save as a PDF. Each block lists its variables and standard; the heading opens the calculator, with its assumptions and a worked example.
Bernoulli's equation and venturi
Bernoulli's equation with a head loss (the energy equation):
p₁ + ½ ρ V₁² + ρ g z₁ = p₂ + ½ ρ V₂² + ρ g z₂ + ρ g h_L
Solved for the pressure at point 2:
p₂ = p₁ + ½ ρ (V₁² − V₂²) + ρ g (z₁ − z₂ − h_L)
Continuity, for the velocity from the two bores:
V₂ = V₁ × (D₁ / D₂)²
Total head:
H = p / (ρ g) + V² / (2 g) + z
- p — pressure, Pa (both gauge or both absolute)
- V — mean velocity, m/s
- z — height above a common datum, m
- h_L — head loss between the points, m
- g = 9.806 65 m/s²
Compressed air calculator: leaks, receiver, pipe drop and power
Leak through a hole, choked when the absolute pressure is above 1.89 times atmospheric (about 13 psig):
ṁ = Cd × A × p0 × √(γ / (R T)) × (2 / (γ + 1))^((γ + 1) / (2(γ − 1))) = 0.6847 Cd A p0 / √(R T)
Q_free = ṁ / ρ_atm, P_wasted = Q_free × specific power
Receiver for a demand event (US DOE MEASUR, Compressed Air Challenge):
V = t × (Q_demand − Q_supply) × p_atm / (p1 − p2)
Pipe pressure drop, isothermal Darcy and the Atlas Copco empirical form:
p1² − p2² = (ṁ / A)² R T × [f L / D + 2 ln(p1 / p2)]
Δp = 450 × qc^1.85 × L / (d⁵ × p) (bar, L/s free air, m, mm, bar absolute)
Compressor power for n intercooled stages:
W_iso = p_a V × ln r
W_ad = n × γ / (γ − 1) × p_a V × (r^((γ − 1) / (n γ)) − 1), P_shaft = W_ad / η
- A, d — hole area and diameter; Cd — coefficient of flow; p0 — absolute pressure upstream
- R = 287.05 J/(kg·K), γ = 1.4 for air; T — air temperature in kelvin
- Q, V — free air flow and volume at atmospheric pressure p_a; r — absolute pressure ratio
- p1, p2 — upper and lower pressures; t — event duration; f — Darcy friction factor
Control valve Cv / Kv sizing
Kv = Q √( (ρ/1000) / Δp_sizing ) Q m³/h, Δp bar; Cv = 1.156 Kv
F_F = 0.96 − 0.28 √(p_v / p_c)
Δp_max = F_L² (p₁ − F_F p_v), Δp_sizing = min(Δp, Δp_max) (choked when Δp ≥ Δp_max)
opening ≈ Kv_required / Kv_rated, velocity = Q / (π D²/4)
maximum flow of a rated valve at p₁: Q_max = Kv_rated √(Δp_max / (ρ/1000))
Typical F_L at full opening: single-seat globe 0.90, cage globe 0.85, eccentric plug 0.77, butterfly 60° 0.68, segmented ball 0.60, butterfly 90° 0.55.
cSt to SSU viscosity converter (Saybolt seconds)
Saybolt Universal seconds at 100 °F from kinematic viscosity ν in cSt (ASTM D2161):
SUS = 4.6324 ν + (1.0 + 0.03264 ν) / ((3930.2 + 262.7 ν + 23.97 ν² + 1.646 ν³) × 10⁻⁵)
At another test temperature t in °F:
SUS_t = SUS_100 × (1 + 0.000061 (t − 100))
Saybolt Furol seconds at 122 °F, and dynamic viscosity:
SFS = 0.4717 ν + 13 924 / (ν² − 72.59 ν + 6 816)
μ (cP) = ν (cSt) × ρ (g/cm³)
- ν — kinematic viscosity at the test temperature, mm²/s (cSt)
- Above 75 cSt the relation is linear: SUS = 4.632 × cSt at 100 °F
Flow rate and pipe velocity
Continuity for a full pipe:
Q = V × A, A = π × D² / 4
Each unknown in turn:
V = Q / A = 4 Q / (π D²)
Q = V × π D² / 4
D = √(4 Q / (π V))
Usual design velocities for liquids, in m/s:
general water and pump discharge 1.0 to 3.0
pump suction 0.6 to 1.5
fuel and lubricating oil 0.5 to 2.0
- Q — volume flow rate, m³/s (1 m³/h = 1/3600 m³/s)
- V — mean velocity, m/s
- D — inside diameter, m
Hazen–Williams head loss calculator
Head loss in SI units, with Q in m³/s and d and L in m:
h_f = 10.67 L Q^1.852 / (C^1.852 d^4.8704)
US form used by NFPA 13, with Q in gpm and d in inches:
p = 4.52 Q^1.85 / (C^1.85 d^4.87) psi per foot of pipe
Both come from the original velocity form, with the hydraulic radius R = d/4 of a full pipe:
V = 0.849 C R^0.63 S^0.54 (SI), V = 1.318 C R^0.63 S^0.54 (US)
Velocity and pressure drop:
V = Q / (π d² / 4), Δp = ρ g h_f
- h_f — friction head loss; S = h_f / L — slope of the hydraulic grade line
- C — Hazen–Williams factor of the pipe material
- d — inside diameter, not the nominal size
- ρ = 999.1 kg/m³ for water at 15 °C; g = 9.81 m/s²
| Pipe material (NFPA 13 Table 28.3.4.8.1) | C |
|---|---|
| Plastic (PVC, CPVC, PE), listed | 150 |
| Copper tube, brass or stainless steel | 150 |
| Cement-lined cast or ductile iron | 140 |
| Asbestos cement, concrete | 140 |
| Black or galvanized steel, wet systems | 120 |
| Black or galvanized steel, dry systems | 100 |
| Unlined cast or ductile iron | 100 |
Hydrostatic pressure at depth
Gauge and absolute pressure:
p_gauge = ρ × g × h
p_abs = p_surface + ρ × g × h
Head in metres of water, and the force on a horizontal surface:
H = p_gauge / (1000 × g)
F = p_gauge × A
- ρ — liquid density, kg/m³ (fresh water 998.2, sea water 1025.87)
- g — 9.806 65 m/s²
- h — depth below the free surface, m
- p_surface — pressure on the surface, Pa (101.325 kPa at sea level)
- A — horizontal area, m²
Minor losses calculator (pipe fittings and valves)
Head loss and pressure loss through fittings:
h = ΣK × v² / (2g)
Δp = ρ g h
Resistance coefficient of a fitting (Crane method):
K = f_T × (L/D)
f_T = [ −2 log10( ε / (3.7 D) ) ]⁻²
Equivalent length of straight pipe:
L_eq = ΣK × D / f_T
- v — mean velocity in the pipe; D — inside diameter; ε = 0.046 mm for clean steel
- L/D — equivalent length in diameters: standard elbow 30, gate valve 8, globe valve 340, swing check 100, tee branch 60
- Entrance K = 0.5 (sharp-edged); exit into a tank K = 1.0
Nozzle flow calculator (orifice, fire nozzle and K-factor)
Orifice equation, any consistent units:
Q = Cd × A × √(2 Δp / ρ), A = π d² / 4
Fire-service form (NFPA 291), Q in gpm, d in inches, p in psi:
Q = 29.84 × c × d² × √p
K-factor form (NFPA 13), US gpm/psi½ or metric L/min/bar½:
Q = K × √p, K_metric = 14.42 × K_US
Jet velocity and nozzle reaction:
v = √(2 Δp / ρ)
F = ρ × Q × v (= 1.57 d² p in lbf for a smooth bore, IFSTA)
F_fog = 0.0505 × Q × √p (IFSTA fog nozzle, lbf, gpm, psi)
- Q — flow; Δp, p — gauge pressure at the nozzle or pitot pressure in the jet
- d — orifice or tip diameter; A — its area
- Cd, c — discharge coefficient; ρ — liquid density, 999 kg/m³ for fresh water
- K — K-factor, which holds the area and the discharge coefficient together
Orifice and venturi flow (ISO 5167)
β = d/D, E = 1/√(1 − β⁴)
q_m = C E ε (π/4) d² √(2 Δp ρ₁), q_v = q_m/ρ₁, Re_D = 4 q_m/(π D μ)
Orifice discharge coefficient (ISO 5167-2 eq. 4, Reader-Harris/Gallagher):
C = 0.5961 + 0.0261 β² − 0.216 β⁸ + 0.000521 (10⁶ β/Re_D)^0.7 + (0.0188 + 0.0063 A) β^3.5 (10⁶/Re_D)^0.3
+ (0.043 + 0.080 e^(−10 L₁) − 0.123 e^(−7 L₁)) (1 − 0.11 A) β⁴/(1 − β⁴) − 0.031 (M′₂ − 0.8 M′₂^1.1) β^1.3
[+ 0.011 (0.75 − β)(2.8 − D/25.4) for D < 71.12 mm]
A = (19 000 β/Re_D)^0.8, M′₂ = 2 L′₂/(1 − β); corner taps L₁ = L′₂ = 0; D–D/2 taps L₁ = 1, L′₂ = 0.47; flange taps L₁ = L′₂ = 25.4/D(mm)
Venturi (ISO 5167-4): C = 0.995 machined, 0.984 as-cast, 0.985 rough-welded.
Expansibility (gases): orifice ε = 1 − (0.351 + 0.256 β⁴ + 0.93 β⁸)[1 − (p₂/p₁)^(1/κ)]; Venturi: isentropic expression of ISO 5167-4 eq. 3. Liquids ε = 1.
Permanent pressure loss (orifice): Δϖ = [√(1 − β⁴(1 − C²)) − C β²]/[√(1 − β⁴(1 − C²)) + C β²] Δp; Venturi about 10 % of Δp.
Pipe flow and pressure drop
Continuity:
V = Q / A, A = π D² / 4
- Q — volume flow rate, m³/s
- V — mean velocity, m/s
- D — pipe inside diameter, m
Reynolds number:
Re = V D / ν
- ν — kinematic viscosity, m²/s (= μ / ρ)
Friction factor (Darcy):
Laminar, Re < 2 300: f = 64 / Re
Turbulent, Colebrook–White: 1/√f = −2 log₁₀( ε/(3.7 D) + 2.51/(Re √f) ) (solved by iteration)
Swamee–Jain explicit: f = 0.25 / [ log₁₀( ε/(3.7 D) + 5.74/Re^0.9 ) ]²
- ε — absolute roughness of the pipe wall, m
Losses:
h_f = f (L/D) V² / (2g) friction head, m of fluid
Δp_f = f (L/D) ρ V² / 2 friction pressure drop, Pa
Δp_K = ΣK ρ V² / 2 minor losses, Pa
Δp_z = ρ g Δz static pressure from elevation, Pa
Δp_total = Δp_f + Δp_K + Δp_z
H_total = Δp_total / (ρ g)
H_loss = (Δp_f + Δp_K) / (ρ g) friction and fittings only (the suction-line loss of an NPSH check)
- L — pipe length, m; ρ — density, kg/m³; ΣK — sum of minor-loss coefficients; Δz — rise of the outlet above the inlet, m; g = 9.80665 m/s²
Roughness presets (Moody 1944 / White Table 6.1): drawn tubing and PVC 0.0015 mm, stainless steel 0.015 mm, commercial steel 0.045 mm, galvanized iron 0.15 mm, cast iron 0.26 mm, concrete 1.0 mm, riveted steel 3 mm.
Pipe volume and mass of contents
Bore area and volume:
A = π × D² / 4
V = A × L
Volume per metre, mass, and fill time:
V per metre = A × 1000 (litres per metre)
m = ρ × V
t = V / Q
- D — inside diameter (bore), m
- L — pipe length, m
- ρ — density of the contents, kg/m³
- Q — flow rate, m³/s
Pump and fan affinity laws
Speed change for the same machine (N₁ → N₂):
Q₂ = Q₁ (N₂/N₁)
H₂ = H₁ (N₂/N₁)² (fans: Δp₂ = Δp₁ (N₂/N₁)²)
P₂ = P₁ (N₂/N₁)³
Impeller diameter change, trimming in the same casing (D₁ → D₂):
Q₂ = Q₁ (D₂/D₁), H₂ = H₁ (D₂/D₁)², P₂ = P₁ (D₂/D₁)³
Geometrically similar machines (complete scaling of the design):
Q₂ = Q₁ (D₂/D₁)³, H₂ = H₁ (D₂/D₁)², P₂ = P₁ (D₂/D₁)⁵
Combined speed and diameter changes multiply the ratios.
Known-point quantities:
P_hyd = ρ g Q H pump hydraulic power, W
P_hyd = Q Δp fan air power, W
η = P_hyd / P_shaft overall efficiency
n_q = N √Q / H^0.75 specific speed (N in rpm, Q in m³/s, H in m)
- Q — volume flow, m³/s; H — head, m of liquid; Δp — total pressure rise, Pa; P — shaft power, W
- N — rotational speed, rpm; D — impeller outside diameter, m; ρ — fluid density, kg/m³; g = 9.80665 m/s²
Pump NPSH and suction lift
NPSHa = (p_abs − p_v) / (ρ g) + z_s − h_f
p_abs = p_atm + p_gauge (absolute pressure on the liquid surface)
margin = NPSHa − NPSHr, ratio = NPSHa / NPSHr
required NPSHa = max(NPSHr + margin_min, NPSHr × ratio_min) (ANSI/HI 9.6.1: 0.6–1 m or 1.1–1.3)
maximum lift: z_max = −(required NPSHa + h_f − (p_abs − p_v)/(ρ g))
Water vapour pressure: IAPWS-IF97 region-4 saturation equation (steam tables; 2.339 kPa at 20 °C, 19.95 at 60 °C, 70.2 at 90 °C, 101.4 at 100 °C).
N_ss = n √Q_gpm / NPSHr_ft^0.75 (US customary; > 11 000 prone to recirculation)
σ = NPSHr / H (Thoma cavitation number)
Pump power calculator
Power at each stage:
P_h = ρ g Q H = Q Δp
P_shaft = P_h / η_pump
P_in = P_shaft / η_motor
US units (brake horsepower):
BHP = Q[gpm] × H[ft] × SG / (3 960 × η_pump)
- ρ — liquid density; g = 9.81 m/s²; Q — flow; H — total head
- Δp — pressure rise, with H = Δp / (ρ g)
- η_pump, η_motor — pump and motor efficiencies at the duty point
Relief valve sizing (API 520)
P₁ = set + overpressure (10 % single, 16 % multiple, 21 % fire) + atmospheric (gas, absolute)
critical if P₂/P₁ ≤ (2/(k+1))^(k/(k−1))
critical: A = W / (C K_d P₁ K_b K_c) × √(T Z / M), C = 0.03948 √(k (2/(k+1))^((k+1)/(k−1)))
sub-critical: A = 17.9 W / (F₂ K_d K_c) × √(T Z / (M P₁ (P₁ − P₂))),
F₂ = √( (k/(k−1)) r^(2/k) (1 − r^((k−1)/k)) / (1 − r) ), r = P₂/P₁
liquid: A = 11.78 Q / (K_d K_w K_c K_v) × √(G / (p₁ − p₂))
A mm², W kg/h, P kPa, T K, Q L/min; K_d 0.975 gas / 0.65 liquid; K_c 0.9 with a rupture disk
API 526 effective areas (in²): D 0.110, E 0.196, F 0.307, G 0.503, H 0.785, J 1.287, K 1.838, L 2.853, M 3.60, N 4.34, P 6.38, Q 11.05, R 16.0, T 26.0 (× 645.16 = mm²).
Reynolds number and flow regime
The Reynolds number:
Re = V L / ν = ρ V L / μ
The characteristic length L depends on the geometry:
circular pipe: L = D
non-circular duct: L = D_h = 4 A / P
flat plate: L = x, the distance from the leading edge
From a volume flow rate:
V = Q / A, A = π D² / 4 for a pipe
Regime limits:
pipe or duct: laminar Re < 2300, transitional 2300 to 4000, turbulent Re > 4000
flat plate: laminar Re_x < 5 × 10⁵, turbulent beyond
- V — mean velocity, m/s
- L — characteristic length, m
- ν — kinematic viscosity, m²/s (1 cSt = 10⁻⁶ m²/s)
- μ — dynamic viscosity, Pa·s; ρ — density, kg/m³
- A — flow area, m²; P — wetted perimeter, m
Total dynamic head (TDH) calculator
Total dynamic head:
TDH = (z_d − z_s) + (p_d − p_s) / (ρ g) + (f L / D + ΣK) × v² / (2g)
Friction factor (Darcy–Weisbach with Colebrook):
Re = v D / ν
1/√f = −2 log10( ε/(3.7 D) + 2.51/(Re √f) ), f = 64/Re if laminar
System curve:
H(Q) ≈ H_static + C Q², C = (f L/D + ΣK) / (2 g A²)
- z_d − z_s — static lift from the suction surface to the discharge surface
- p_d − p_s — difference in gauge pressure between the two vessels
- f — Darcy friction factor; L — pipe length; D — inside diameter; ΣK — fittings
- ν — kinematic viscosity; ε — pipe roughness
Water hammer (Joukowsky)
a₀ = √(K/ρ), a = a₀ / √(1 + (K/E)(D/e) c₁) Korteweg (thin wall)
t_crit = 2L/a, period = 4L/a
rapid (t_c ≤ t_crit): Δp = ρ a Δv Joukowsky
slow (t_c > t_crit): Δp = 2 ρ L Δv / t_c Michaud (≤ Joukowsky)
p_max = p_steady + Δp, p_min = p_steady − Δp (vapour pressure → column separation)
c₁: 1.0 with expansion joints, 0.85 anchored upstream, 0.91 anchored throughout. K: water 2.19 GPa, sea water 2.34, oils 1.5–1.7. E: steel 207 GPa, ductile iron 170, copper 117, GRP 20, PVC 3, HDPE 0.9.
Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person.