Compressed air calculator: leaks, receiver, pipe drop and power

Compressed air leak flow and yearly cost, receiver tank size, air main pressure drop and compressor power, isothermal and adiabatic.

Units

Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person. Report a problem

Introduction

Compressed air is one of the most expensive forms of energy in a plant, and leaks often waste 20 to 30 % of a compressor's output. A single 1/4 inch hole at 100 psig blows away 104 cfm of free air, which costs about $16 800 a year at 10 cents per kWh.

This calculator handles four everyday tasks. It gives the leak flow through a hole and its yearly energy and cost. It sizes a receiver tank for a demand event. It finds the pressure drop in an air main by the Darcy equation and by the Atlas Copco formula. It estimates compressor power, isothermal and adiabatic, with one to four stages. It is for maintenance and energy engineers and plant managers.

Formulas

Leak through a hole, choked when the absolute pressure is above 1.89 times atmospheric (about 13 psig):

ṁ = Cd × A × p0 × √(γ / (R T)) × (2 / (γ + 1))^((γ + 1) / (2(γ − 1))) = 0.6847 Cd A p0 / √(R T)
Q_free = ṁ / ρ_atm,   P_wasted = Q_free × specific power

Receiver for a demand event (US DOE MEASUR, Compressed Air Challenge):

V = t × (Q_demand − Q_supply) × p_atm / (p1 − p2)

Pipe pressure drop, isothermal Darcy and the Atlas Copco empirical form:

p1² − p2² = (ṁ / A)² R T × [f L / D + 2 ln(p1 / p2)]
Δp = 450 × qc^1.85 × L / (d⁵ × p)      (bar, L/s free air, m, mm, bar absolute)

Compressor power for n intercooled stages:

W_iso = p_a V × ln r
W_ad = n × γ / (γ − 1) × p_a V × (r^((γ − 1) / (n γ)) − 1),   P_shaft = W_ad / η
  • A, d — hole area and diameter; Cd — coefficient of flow; p0 — absolute pressure upstream
  • R = 287.05 J/(kg·K), γ = 1.4 for air; T — air temperature in kelvin
  • Q, V — free air flow and volume at atmospheric pressure p_a; r — absolute pressure ratio
  • p1, p2 — upper and lower pressures; t — event duration; f — Darcy friction factor

Assumptions and limitations

  • All flows are free air delivery: the volume at the atmospheric pressure and temperature entered. Compressor ratings use the same basis.
  • A leak is modelled as a round hole. A coefficient of 1 reproduces the published leak tables, and the US DOE multiplies by 0.61 for sharp-edged holes. Real leaks in fittings and hoses vary, so treat the result as an estimate.
  • The leak cost assumes the compressor power falls in proportion when the leaks are fixed. That holds only with good control, such as a variable-speed compressor or proper sequencing.
  • The pipe drop needs fittings added as equivalent length. Atlas Copco recommends no more than 0.1 bar (1.5 psi) from the compressor to the farthest user.

Worked example

A plant runs at 100 psig all year. Ultrasonic testing finds a leak equivalent to a 1/4 inch hole. The ambient is 14.696 psia and 68 °F. The compressors use 18.4 kW per 100 cfm, and power costs $0.10 per kWh.

  1. Upstream pressure: 100 + 14.7 = 114.7 psia, or 790.8 kPa. That is 7.8 times atmospheric, so the flow is choked.
  2. Hole area: π / 4 × 6.35² = 31.67 mm².
  3. Mass flow: 0.6847 × 31.67 × 10⁻⁶ × 790 800 / √(287.05 × 293.15) = 0.0591 kg/s.
  4. Free air: 0.0591 / 1.204 = 0.0491 m³/s, or 104.0 cfm.
  5. Compressor power: 104.0 / 100 × 18.4 = 19.1 kW.
  6. Energy: 19.1 × 8 760 h = 167 700 kWh a year, which costs $16 767.

The CAGI fact sheet prints $16 764 for the same leak. Fixing it pays back in days.

FAQ

How much does a compressed air leak cost?

Multiply the leak flow by the compressor specific power, the running hours and the electricity price. A 1/8 inch hole at 100 psig wastes 26 cfm, about $4 190 a year running constantly at 18.4 kW per 100 cfm and 10 cents per kWh.

How do I measure total leakage?

With no production running, time how long the compressor loads (T) and unloads (t). Leakage in percent of capacity is 100 × T / (T + t); CAGI says a well-kept system stays below 10 %.

What is the specific power of a compressor?

The electrical power per unit of free air delivered. Typical plants run at about 18 kW per 100 cfm, or 6.4 kW per m³/min.

How big should my air receiver be?

Big enough to supply the peak demand above the compressor output while the pressure falls to the lowest acceptable value. 100 cfm for one minute with a 10 psi drop needs 147 ft³, about 1 100 US gallons.

Does lowering the system pressure reduce leaks?

Yes. A choked leak flows in proportion to the absolute pressure, so dropping from 100 to 90 psig cuts leakage by about 9 %.

What is the difference between isothermal and adiabatic power?

Isothermal power is the ideal minimum with the air kept at inlet temperature. Adiabatic power assumes no cooling during compression and is the usual reference for real compressors. Intercooled stages bring it closer to isothermal.

Related calculators

What this calculator is checked against

Before every release the calculator must reproduce each case below. The note under each case says where the expected answer comes from: a standard, a textbook, a published table, or a hand calculation shown in full.

  1. Leakage table at coefficient 1: 100 psig 1/16 in 6.49, 1/4 in 104, 3/8 in 234 cfm; 15 psig 1/4 in 26.9 cfm; 50 psig 1/64 in 0.229 cfmUS DOE Compressed Air Tip Sheet #3 leakage table; "Discharge of air through an orifice" table (Burton Companies)
  2. Leak cost at 0.10 per kWh, constant operation: 1/16 in 1 046, 1/8 in 4 190, 1/4 in 16 764 a year (18.4 kW per 100 cfm)CAGI / Compressed Air Challenge Fact Sheet #7, "The cost of leaks" (rev. May 2026)
  3. Subsonic leak at 5 psig follows the isentropic nozzle equation and is below the choked valueF. M. White, Fluid Mechanics, Ch. 9 (isentropic flow through a nozzle); hand calculation
  4. Receiver: 100 cfm for 1 min, 100 to 90 psig at 14.7 psia needs 147 ft³ = 1 099 US gal; with a 40 cfm metered supply 660 galUS DOE / ORNL MEASUR Receiver Tank Calculator, dedicated and metered storage methods; hand calculation
  5. Air main: 100 L/s free air, 59 m of 53 mm bore at 7 bar g gives 0.040 bar by the BCAS/Atlas Copco formula; Darcy within 10 %BCAS simplified equation PD = 1.6 × 10⁸ L Q^1.85 / (P d⁵) (pocketEngineer worked example data); Atlas Copco d⁵ = 450 qc^1.85 l/(Δp p)
  6. Compressor work for 100 cfm free air to 100 psig: isothermal 9.83 kW, one-stage adiabatic 13.37 kW, two stages 11.42 kWÇengel & Boles, Thermodynamics, Ch. 7: W = p1V1 ln r and n γ/(γ−1) p1V1 (r^((γ−1)/nγ) − 1); hand calculation
  7. Invalid input: a minimum pressure above the line pressure, a supply above the demand and a choked pipe are rejectedBehaviour check: warnings and rejected inputs
  8. Worked example of the article: the calculator reproduces 104.0 cfm, 19.1 kW, 167 700 kWh, 16 767 to the digits printedThe worked example on this page, to the digits printed

Assumptions and sources

Assumptions and limits

  • Air is an ideal gas with R = 287.05 J/(kg·K) and γ = 1.4. Flows are free air delivery (FAD): volume at the atmospheric pressure and air temperature entered, the way compressors are rated (ISO 1217).
  • A leak is a round hole of diameter d with a coefficient of flow Cd; Cd = 1 reproduces the published leakage tables (104 cfm through 1/4 in at 100 psig), and the US DOE multiplies by 0.61 for sharp-edged holes. Above 13 psig the flow through a hole to the atmosphere is choked (sonic) and grows linearly with the absolute pressure.
  • The leak cost uses a compressor specific power: about 18 kW per 100 cfm of free air for a typical plant (US DOE), 15 to 16 for an efficient one; the power is assumed to fall in proportion when the leaks are fixed, which needs good compressor control.
  • The receiver size is the volume that supplies the demand minus any compressor or metered supply during the event while the pressure falls from the line pressure to the lowest acceptable pressure, at constant temperature.
  • Pipe pressure drop is isothermal flow with the Darcy friction factor (Colebrook, roughness 0.046 mm for steel) and Sutherland viscosity; the Atlas Copco/BCAS empirical formula is shown for comparison. Fittings must be added as equivalent length.

Sources

  • US DOE, Compressed Air Tip Sheet #3 "Minimize Compressed Air Leaks" (leakage table at coefficient 1, ×0.61 sharp-edged, 18 kW/100 cfm) and CAGI / Compressed Air Challenge Fact Sheet #7 "Compressed Air System Leaks" (rev. 2026)
  • US DOE / ORNL MEASUR Tools Suite, Receiver Tank Calculator: dedicated and metered storage V = t (Q − Q_metered) p_atm / (p_in − p_out)
  • Atlas Copco, Compressed Air Manual, 8th ed.: pipe dimensioning d⁵ = 450 qc^1.85 l / (Δp p) (BCAS form 1.6 × 10⁸ L Q^1.85 / (d⁵ p)) and the 0.1 bar network guideline
  • F. M. White, Fluid Mechanics, 7th ed., Ch. 9 (choked flow through an orifice, isothermal flow with friction); Y. A. Çengel & M. A. Boles, Thermodynamics, Ch. 7 (isothermal, isentropic and multistage compressor work)

Cite this calculator

Papandreou, C. (2026). Compressed air calculator: leaks, receiver, pipe drop and power. Engineering Bible. https://engineeringbible.com/fluids/compressed-air/

Embed this calculator on your site

Copy this HTML into your page. The calculator stays free to use and links back here.

By Christos Papandreou. Updated . How the numbers are checked.