Structural engineering formulas
The formulas behind the 17 structural calculators, on one page you can print or save as a PDF. Each block lists its variables and standard; the heading opens the calculator, with its assumptions and a worked example.
Beam deflection and bending stress
Section properties:
Rectangle b × h: I = b h³ / 12, c = h / 2
Hollow rectangle: I = [b h³ − (b−2t)(h−2t)³] / 12, c = h / 2
Solid circle d: I = π d⁴ / 64, c = d / 2
Tube D, wall t: I = π [D⁴ − (D−2t)⁴] / 64, c = D / 2
I-section: I = [b h³ − (b − t_w)(h − 2t_f)³] / 12, c = h / 2
Z = I / c
Bending stress at the extreme fibre:
σ = M_max × c / I = M_max / Z
Load cases (L span, P point load, w load per unit length, a distance of the point load, b = L − a, E Young's modulus):
| Case | M_max | δ_max | Location of δ_max |
|---|---|---|---|
| Simply supported, P at midspan | P L / 4 | P L³ / (48 E I) | midspan |
| Simply supported, P at a | P a b / L | P s (L² − s²)^{3/2} / (9√3 E I L), s = min(a, b) | √((L² − s²)/3) from the far support |
| Simply supported, UDL w | w L² / 8 | 5 w L⁴ / (384 E I) | midspan |
| Cantilever, P at free end | P L | P L³ / (3 E I) | free end |
| Cantilever, P at a from fixed end | P a | P a² (3L − a) / (6 E I) | free end |
| Cantilever, UDL w | w L² / 2 | w L⁴ / (8 E I) | free end |
| Fixed–fixed, P at midspan | P L / 8 | P L³ / (192 E I) | midspan |
| Fixed–fixed, UDL w | w L² / 12 (ends) | w L⁴ / (384 E I) | midspan |
Utilisation and safety factor:
Utilisation = σ / f_y, FoS = f_y / σ
- f_y — yield strength of the material
Column base plate calculator (AISC Design Guide 1)
Bearing on concrete (AISC 360-16 J8), with φc = 0.65:
φc Pp = φc × 0.85 f'c A1 √(A2/A1) ≤ φc × 1.7 f'c A1
A1,req = Pu / (φc 0.85 f'c) when A2 = A1
Plate dimensions:
Δ = (0.95 d − 0.8 bf) / 2, N ≈ √A1,req + Δ, B = A1,req / N
Cantilevers and thickness, with φ = 0.90:
m = (N − 0.95 d)/2, n = (B − 0.8 bf)/2
X = 4 d bf / (d + bf)² × Pu / (φc Pp), λ = 2√X / (1 + √(1 − X)) ≤ 1
λn' = λ √(d bf) / 4, l = max(m, n, λn')
t_min = l √( 2 Pu / (0.9 Fy B N) )
- Pu — factored axial load; d, bf — column depth and flange width
- A1 — plate area; A2 — the largest concrete area similar to and concentric with the plate
- f'c — concrete strength; Fy — plate yield strength
Column buckling (Euler and Johnson)
Section and slenderness:
r = √(I_min / A) radius of gyration about the weak axis
L_e = K L effective length; K from the end conditions
λ = K L / r slenderness ratio
Euler (long columns):
P_cr = π² E I_min / (K L)², σ_cr = π² E / λ²
Transition slenderness and Johnson parabola (intermediate columns, λ < λ₁):
λ₁ = π √(2 E / σ_y)
σ_cr = σ_y − (σ_y² / (4 π² E)) λ², P_cr = σ_cr A
Allowable load and utilisation:
P_allow = P_cr / FS, utilisation = P / P_allow
Effective-length factors K (theoretical / recommended): pinned–pinned 1.0 / 1.0; fixed–fixed 0.5 / 0.65; fixed–pinned 0.7 / 0.8; fixed–free 2.0 / 2.1; fixed–guided 1.0 / 1.2.
- E — Young's modulus; σ_y — yield strength (compressive strength parallel to grain for timber); I_min — second moment of area about the weak axis; A — cross-section area
Deflection limits calculator (L/360, L/240)
Allowable deflection and utilisation:
Δ_allow = l / n
utilisation = Δ_actual / Δ_allow
span ratio = l / Δ_actual
IBC Table 1604.3, main rows (live L, snow or wind S or W, dead plus live D + L):
floor members L/360 — L/240
roof, plaster or stucco ceiling L/360 L/360 L/240
roof, non-plaster ceiling L/240 L/240 L/180
roof, no ceiling L/180 L/180 L/120
- l — span; for IBC cantilevers, twice the cantilever length
- UK NA steel: span/360 with brittle finishes, span/200 for other beams, length/180 for cantilevers
- EN 1992 concrete: span/250 for sag, span/500 after the finishes are built
- EN 1995 timber: w_inst l/300 to l/500, w_net,fin l/250 to l/350, w_fin l/150 to l/300
Fillet weld strength
a = z/√2 (throat from leg), f_vw,d = f_u / (√3 β_w γ_M2), F_w,Rd = f_vw,d a
Forces per weld (n parallel welds, moment couple over spacing h):
F_⊥ = F_transverse/n + M/h, F_∥ = F_longitudinal/n
simplified: F_w,Ed = √(F_⊥² + F_∥²)/L ≤ F_w,Rd
directional: σ⊥ = τ⊥ = F_⊥/(√2 a L), τ∥ = F_∥/(a L)
√(σ⊥² + 3(τ⊥² + τ∥²)) ≤ f_u/(β_w γ_M2) and σ⊥ ≤ 0.9 f_u/γ_M2
Steel data (t ≤ 40 mm): S235 f_u 360 MPa β_w 0.80; S275 430/0.85; S355 490/0.90; S420 520/1.00; S460 540/1.00; γ_M2 = 1.25.
Limits: a ≥ 3 mm; a ≤ 0.7 t_min (practice); L_eff ≥ 30 mm and ≥ 6a; L_eff ≤ 150a without the long-weld reduction β_Lw.
Joist span calculator (bending and deflection)
Load per joist and section properties:
w = q × s, S = b d² / 6, I = b d³ / 12
Span limited by bending, with F'b = Fb × C_D × C_F × C_r:
M = w L² / 8 ≤ F'b S → L_b = √( 8 F'b S / w )
Span limited by deflection, with the limit L/n:
Δ = 5 w L⁴ / (384 E I) ≤ L / n → L_Δ = ( 384 E I / (5 w n) )^(1/3)
- q — load per unit floor area; s — joist spacing; b, d — actual width and depth
- C_D — load duration, 1.0 for occupancy live load; C_F — size factor; C_r = 1.15 for joists at 24 in or less
- Live load deflection uses the live load only; total load deflection uses dead plus live
Load combinations calculator (ASCE 7 LRFD/ASD and Eurocode)
ASCE 7-16 LRFD (section 2.3.1):
1. 1.4D
2. 1.2D + 1.6L + 0.5(Lr or S or R)
3. 1.2D + 1.6(Lr or S or R) + (L or 0.5W)
4. 1.2D + 1.0W + L + 0.5(Lr or S or R)
5. 1.2D + 1.0E + L + 0.2S
6. 0.9D + 1.0W
7. 0.9D + 1.0E
ASCE 7-16 ASD (section 2.4.1):
D; D + L; D + (Lr or S or R); D + 0.75L + 0.75(Lr or S or R)
D + (0.6W or 0.7E); D + 0.75L + 0.75(0.6W) + 0.75(Lr or S or R)
D + 0.75L + 0.75(0.7E) + 0.75S; 0.6D + 0.6W; 0.6D + 0.7E
EN 1990 (STR, persistent and transient):
6.10: 1.35 G + 1.5 Q_1 + Σ 1.5 ψ0,i Q_i
6.10a: 1.35 G + Σ 1.5 ψ0,i Q_i
6.10b: 0.85 × 1.35 G + 1.5 Q_1 + Σ 1.5 ψ0,i Q_i
6.12b: G + A_Ed + Σ ψ2,i Q_i (seismic)
- D or G — dead load; L — live load; Lr — roof live load; S — snow; R — rain; W — wind; E — earthquake
- ψ0: 0.7 for categories A to D, F and G, 1.0 for storage, 0.5 or 0.7 for snow, 0.6 for wind, 0 for roofs
- Favourable dead load takes γ = 1.0, and favourable variable loads are left out
Moment of inertia calculator (section properties)
Solid rectangle b × h and round bar of diameter d:
I_x = b h³ / 12, S_x = b h² / 6, Z_x = b h² / 4
I = π d⁴ / 64, S = π d³ / 32, Z = d³ / 6, J = π d⁴ / 32
Composite sections (I, T, channel, box), from their rectangles:
ȳ = Σ A_i y_i / Σ A_i
I_x = Σ ( b_i h_i³ / 12 + A_i (y_i − ȳ)² ) parallel-axis theorem
S_x = I_x / c_max, r_x = √(I_x / A)
Z_x = Σ A_i |y_i − y_p|, y_p splits the area in half
- c_max — distance from the centroid to the farthest fibre
- S — elastic section modulus, for the stress at first yield: σ = M / S
- Z — plastic section modulus, for the fully plastic moment: M_p = f_y Z
- r — radius of gyration, used for column slenderness L / r
Padeye design check
Geometry (Table 3.9, type A): a ≥ F γM0 / (2 t fy) + 2 d0/3, c ≥ F γM0 / (2 t fy) + d0/3
Bearing: Fb,Rd = 1.5 t d fy / γM0
Pin shear (each plane): Fv,Rd = 0.6 A fup / γM2
Pin bending (Figure 3.11): MEd = F (b + 4c + 2a) / 8, MRd = 1.5 Wel fyp / γM0
Combined: (MEd/MRd)² + (Fv,Ed/Fv,Rd)² ≤ 1
Replaceable pin: σh,Ed = 0.591 √(E Fser (d0 − d) / (d² t)) ≤ 2.5 fy / γM6,ser
- a, c — material beyond the hole in the load direction and at the sides; t — plate thickness; d0, d — hole and pin diameters; in the pin moment, b is the padeye thickness, a the jaw thickness and c the gap.
Rebar weight and quantity calculator
Metric bar mass per metre (the d²/162 rule):
m' = 7 850 × π d² / 4 = 0.006165 d² kg/m, d in mm
Bars in a grid, each way:
N = floor( (S − 2c) / s ) + 1, each of length L − 2c
total length = Σ N × (L − 2c) × layers × (1 + allowance)
Steel area per width:
A_s = A_bar / s in² per ft or mm² per m
- S — the span across which the bars are spaced; L — the length they run
- s — spacing; c — edge cover
- US bars: area and unit weight from ASTM A615 Table 1 (#4: 0.20 in², 0.668 lb/ft)
Snow load calculator (Eurocode and ASCE 7)
Eurocode EN 1991-1-3:
s = μ1 × C_e × C_t × s_k
μ1 = 0.8 for α ≤ 30°, 0.8 (60 − α)/30 for 30° < α < 60°, 0 for α ≥ 60°
ASCE 7-16:
p_f = 0.7 × C_e × C_t × I_s × p_g flat roof
p_s = C_s × p_f sloped roof
p_m = I_s p_g (p_g ≤ 20 psf) or 20 I_s minimum for slopes under 15°
- s_k, p_g — ground snow load from the national map; α — roof slope
- C_e — exposure: 0.8 windswept to 1.2 sheltered (EN); 0.9 to 1.2 (ASCE)
- C_t — thermal: 1.0 heated, 1.1 cold ventilated roof, 1.2 unheated, 1.3 freezer (ASCE)
- I_s — importance: 0.8, 1.0, 1.1, 1.2 for risk categories I to IV
- C_s — slope factor: 1 up to 30° (warm, rough roof) then falling to 0 at 70°; slippery and cold roofs differ
Steel and metal weight calculator
Weight of n pieces of length L:
m = ρ × A × L × n
Cross-section areas:
plate, flat bar: A = w t
round bar: A = π d² / 4
hex bar: A = (√3 / 2) s² s across flats
round tube: A = π t (D − t)
rectangular tube: A = b h − (b − 2t)(h − 2t)
angle: A = t (a + b − t)
I-beam, channel: A = 2 b t_f + (h − 2 t_f) t_w
- ρ — density: carbon steel 7 850, stainless 304 7 900, aluminium 2 700, copper 8 940 kg/m³
- D, t — outside diameter and wall of a tube; b, h — width and height
Steel beam size calculator
Moment and shear for a uniform load w and a point load P at midspan, span L:
M = w L² / 8 + P L / 4
V = w L / 2 + P / 2
Load combinations, with the self-weight in the dead load D (or G):
AISC LRFD: w_u = max(1.2 D + 1.6 L, 1.4 D)
AISC ASD: w_a = D + L
Eurocode: w_Ed = 1.35 G + 1.5 Q
Bending strength of a compact, continuously braced section:
AISC 360 F2.1: M_n = F_y Z_x, LRFD φ_b M_n with φ_b = 0.90, ASD M_n / Ω_b with Ω_b = 1.67
EN 1993-1-1 6.2.5: M_c,Rd = W_pl,y f_y / γ_M0, γ_M0 = 1.0
Shear strength of the web:
AISC 360 G2.1: V_n = 0.6 F_y d t_w C_v1, φ_v = 1.00 and Ω_v = 1.50 when h/t_w ≤ 2.24 √(E/F_y)
EN 1993-1-1 6.2.6: V_pl,Rd = A_v (f_y / √3) / γ_M0
Live-load deflection, checked against L divided by the chosen limit:
δ = 5 w L⁴ / (384 E I) + P L³ / (48 E I)
- Z_x, W_pl,y — plastic section modulus; I — moment of inertia about the strong axis
- F_y, f_y — yield strength: 50 ksi (A992), 36 ksi (A36), 235, 275 or 355 MPa
- E — 29 000 ksi for AISC, 210 000 MPa for Eurocode 3
- A_v — shear area of the IPE from the catalogue; d t_w — web area of the W-shape
Stiffener with attached plating
Neutral axis: z̄ = Σ A_i z_i / Σ A_i
Moment of inertia: I = Σ (I_i + A_i (z_i − z̄)²)
Section moduli: Z_plate = I / z̄, Z_flange = I / (h_total − z̄)
Rectangle: I_i = b h³ / 12
- z — height above the outer surface of the plate; h_total — plate thickness plus profile height.
Truss calculator (Pratt, Howe, Warren)
Every joint is in equilibrium:
Σ F_x = 0, Σ F_y = 0 at each of the j joints
A plane truss is statically determinate when:
m + r = 2j
Method of sections, for a chord member opposite a joint at distance x:
F_chord = M(x) / H
- m — number of members; r — reactions (3 for a pin and a roller); j — joints
- M(x) — bending moment of the equivalent beam at x; H — truss depth
- Panel loads: W/n at interior top joints, W/(2n) at the end joints
Weld fatigue damage (DNV-RP-C203)
S-N curve (air, CP): log N = log a1 − m1 log Δσ above the slope change (10^7 cycles in air, 10^6 with CP)
log N = log a2 − 5 log Δσ below it
Free corrosion: log N = log a − 3 log Δσ
Effective range: Δσ_eff = Δσ · SCF · (t / t_ref)^k for t > t_ref
Miner sum: D = Σ n_i / N_i ≤ η = 1 / DFF
Fatigue life: period / D
Wind load calculator (Eurocode and ASCE 7)
Eurocode EN 1991-1-4, terrain roughness z₀ and the basic wind speed v_b:
k_r = 0.19 (z₀ / 0.05)^0.07, c_r = k_r ln(z / z₀)
v_m = c_r v_b, I_v = 1 / ln(z / z₀)
q_p = (1 + 7 I_v) × ½ ρ v_m², ρ = 1.25 kg/m³
ASCE 7-16, exposure B, C or D:
K_z = 2.01 (z / z_g)^(2/α) (z at least 15 ft)
q_z = 0.00256 K_z K_zt K_d K_e V² psf, V in mph
Force on an area:
F = q × C × A
- Terrain categories 0 to IV: z₀ = 0.003, 0.01, 0.05, 0.3, 1.0 m
- Exposure B, C, D: α = 7.0, 9.5, 11.5 and z_g = 1 200, 900, 700 ft
- K_zt — topography (1 on flat ground); K_d — directionality (0.85 for buildings)
Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person.