Column base plate calculator (AISC Design Guide 1)

Size a steel column base plate for a concentric axial load by AISC Design Guide 1 (LRFD): bearing area, plate N × B, cantilevers and required thickness.

Units
A base plate 22.00 in × 20.00 in × 1.604 in under a 12.7 in column.B 20.00 inN 22.00 incolumn 12.7 in × 12.2 indashed: the concretePlate 22.00 in × 20.00 in × 1.604 inBearing used 96.0 % of capacityPlan, to scale (AISC Design Guide 1)
Drawn for the default inputs. It redraws as you change them.

Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person. Report a problem

Introduction

A base plate spreads a steel column's load over the concrete below. It must be large enough for the concrete to take the bearing pressure, and thick enough not to bend where it overhangs the column. For a W12×96 column carrying 700 kips on 3 ksi concrete, AISC Design Guide 1 gives a 22 × 20 in plate, 1.60 in thick in A36 steel.

This calculator follows the Design Guide 1 procedure for a concentric axial load in LRFD. It finds the required bearing area, sizes the plate with the Guide's near-optimum rule, checks bearing with the confinement of a larger pedestal or footing, and computes the cantilevers m, n and λn' and the required thickness. It is for structural engineers, detailers and students designing column bases.

Formulas

Bearing on concrete (AISC 360-16 J8), with φc = 0.65:

φc Pp = φc × 0.85 f'c A1 √(A2/A1) ≤ φc × 1.7 f'c A1
A1,req = Pu / (φc 0.85 f'c)        when A2 = A1

Plate dimensions:

Δ = (0.95 d − 0.8 bf) / 2,   N ≈ √A1,req + Δ,   B = A1,req / N

Cantilevers and thickness, with φ = 0.90:

m = (N − 0.95 d)/2,   n = (B − 0.8 bf)/2
X = 4 d bf / (d + bf)² × Pu / (φc Pp),   λ = 2√X / (1 + √(1 − X)) ≤ 1
λn' = λ √(d bf) / 4,   l = max(m, n, λn')
t_min = l √( 2 Pu / (0.9 Fy B N) )
  • Pu — factored axial load; d, bf — column depth and flange width
  • A1 — plate area; A2 — the largest concrete area similar to and concentric with the plate
  • f'c — concrete strength; Fy — plate yield strength

Assumptions and limitations

  • The load is a concentric compression on a wide-flange column. Moments, uplift, shear and anchor rods need the other parts of Design Guide 1.
  • Pu must come from the LRFD load combinations. Allowable stress design uses different factors and is not covered.
  • The plate is rounded up to whole inches or 10 mm, then checked again. A pedestal that is not the same shape as the plate can need a slightly larger plate, which the page finds.
  • Grout, pedestal reinforcement and the weld between column and plate are not designed here.

Worked example

This is Design Guide 1, Example 4.1. A W12×96 column (d = 12.7 in, bf = 12.2 in) carries Pu = 700 kips. The plate covers the whole concrete support, so A2 = A1. f'c = 3 ksi and the plate is A36.

  1. Required area: 700 / (0.65 × 0.85 × 3) = 422 in².
  2. Δ = (0.95 × 12.7 − 0.8 × 12.2) / 2 = 1.15 in, so N = √422 + 1.15 = 21.7, rounded up to 22.00 in.
  3. B = 422 / 22 = 19.2, rounded up to 20.00 in.
  4. Bearing strength: 0.65 × 0.85 × 3 × 440 = 729 kip, more than 700 kips.
  5. Cantilevers: m = (22 − 12.07)/2 = 4.97 in, n = (20 − 9.76)/2 = 5.12 in, λn' = 3.11 in. n governs.
  6. Thickness: 5.12 × √(2 × 700 / (0.9 × 36 × 22 × 20)) = 1.60 in.

On a large footing, where A2 is at least four times A1, the same column needs only a 16 × 14 in plate, 1.37 in thick.

A base plate 22.00 in × 20.00 in × 1.604 in under a 12.7 in column.
The worked example, drawn by the same code as the live drawing above.

FAQ

How do I size a base plate?

Divide the factored load by the design bearing stress of the concrete for the plate area. Then choose N and B so the overhangs m and n are about equal, and compute the thickness from the largest overhang.

What is A2 in base plate design?

The area of the supporting concrete that is geometrically similar to the plate and centred on it. A larger area confines the concrete under the plate and raises its bearing strength, up to twice the unconfined value.

What does λn' represent?

The cantilever of the plate between the column flanges, from Thornton's yield-line analysis. It governs for small plates that barely extend past the column.

Why 0.95 d and 0.8 bf?

The plate is assumed to bend about lines just inside the column edges, at 95 % of the depth and 80 % of the flange width. These are the critical sections of Design Guide 1.

What grade of steel is used for base plates?

ASTM A36, with Fy = 36 ksi, is a common plate grade in the US, and S275 or S355 in Europe. Enter the yield strength of the plate actually used.

Does this work for ASD?

No. This page uses LRFD factors. Design Guide 1 gives the ASD equations, with Ω = 2.31 for bearing on concrete and 1.67 for plate bending.

Related calculators

What this calculator is checked against

Before every release the calculator must reproduce each case below. The note under each case says where the expected answer comes from: a standard, a textbook, a published table, or a hand calculation shown in full.

  1. Design Guide 1 Example 4.1: W12×96, Pu 700 kips, f'c 3 ksi, A2 = A1, A36: A1 = 422 in², plate 22 × 20 in, φcPp = 729 kips, n = 5.12 in governs, t = 1.60 inAISC Design Guide 1, 2nd ed. (2006), Example 4.1 Base plate for concentric axial compressive load (no concrete confinement), LRFD
  2. Bearing on concrete: √(A2/A1) = 1.5 raises φcPp by 50 %, A2 = 4 A1 doubles it, and the factor stops at 2 (1.7 f'c)AISC 360-16 J8: φc Pp = 0.65 × 0.85 f'c A1 √(A2/A1) ≤ 0.65 × 1.7 f'c A1
  3. Thornton λ: X = 0.5 gives λ = 2√0.5/(1 + √0.5) = 0.828; X ≥ 1 gives λ = 1; λn' = λ √(d bf)/4AISC Design Guide 1, section 3.1.2: λ = 2√X / (1 + √(1 − X)) ≤ 1 (Thornton 1990)
  4. Given 24 × 24 in plate for the Example 4.1 column: m = 5.97 in, n = 7.12 in governs, t = 7.12 √(2 × 700/(0.9 × 36 × 576)) = 1.95 inHand calculation with Design Guide 1 eq. t_min = l √(2 Pu / (0.9 Fy B N))
  5. A large footing (A2 ≥ 4 A1) halves the required area to 211 in²; a pedestal sizes a plate that passes bearing; plates smaller than the column or the pedestal are refusedBehaviour check: warnings and rejected inputs
  6. Worked example of the article: the calculator reproduces 422 in², 22.00 in, 20.00 in, 729 kip, 1.60 in to the digits printedThe worked example on this page, to the digits printed

Assumptions and sources

Assumptions and limits

  • The column is a wide-flange (I-shaped) section carrying a concentric axial compression only; moments, uplift, shear and anchor rods need the other cases of Design Guide 1.
  • LRFD with φc = 0.65 for bearing on concrete (AISC 360-16 J8) and φ = 0.90 for plate bending; the factored load Pu comes from the LRFD load combinations.
  • The support area A2 is the largest area of the pedestal or footing that is geometrically similar to and concentric with the plate; √(A2/A1) is limited to 2.
  • The plate is sized with Design Guide 1's near-optimum rule N ≈ √A1 + Δ and rounded up to whole inches or 10 mm, then checked again for bearing. Grout, the pedestal reinforcement and the column-to-plate weld are not designed here.

Sources

  • Fisher, J.M. and Kloiber, L.A. (2006), AISC Steel Design Guide 1: Base Plate and Anchor Rod Design, 2nd ed., section 3.1 (concentric compressive axial loads) and Example 4.1
  • ANSI/AISC 360-16 Specification for Structural Steel Buildings, section J8 Column Bases and Bearing on Concrete
  • ACI 318-19 Building Code Requirements for Structural Concrete, 22.8 Bearing (√(A2/A1) ≤ 2)

Cite this calculator

Papandreou, C. (2026). Column base plate calculator (AISC Design Guide 1). Engineering Bible. https://engineeringbible.com/structural/base-plate/

Embed this calculator on your site

Copy this HTML into your page. The calculator stays free to use and links back here.

By Christos Papandreou. Updated . How the numbers are checked.