Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person. Report a problem
Introduction
The safe working load of a wire rope is its minimum breaking load divided by a safety factor, called the coefficient of utilisation. For stranded rope, EN 12385-4 gives the breaking load as a factor K times the diameter squared times the rope grade. A 20 mm 6×36 rope with a steel core in grade 1770 breaks at no less than 0.356 × 20² × 1 770 / 1 000 = 252 kN. With the factor of 5 used for slings, and before any loss at the end fitting, it may lift about 5.1 t.
This calculator gives the minimum breaking load of 6×19 and 6×36 class ropes from EN 12385-4, or takes it from the rope certificate. It applies a termination efficiency and a safety factor: 5 for slings to EN 13414-1, or the ILO formula for ships' derricks and cranes. For alloy lifting chain it gives the working load limit of Grade 8, Grade 80 and Grade 100 chain. It is for ship's officers, riggers, crane operators and superintendents.
Formulas
Minimum breaking force of stranded rope (EN 12385-4):
MBL = K × d² × R_r / 1 000 kN, d in mm, R_r in N/mm²
Safe working load:
SWL = MBL × η_t / Z
ILO coefficient of utilisation for wire rope (ILO C152):
Z = 10⁴ / (8.85 × SWL + 1 910) SWL in tonnes, up to 160 t
Z = 3 above 160 t; slings: Z = 5 up to 10 t
Lifting chain:
breaking force ≥ 4 × WLL
K — 0.330 for fibre core, 0.356 for steel core (IWRC), 6×19 and 6×36 classes
R_r — rope grade: 1770, 1960 or 2160 N/mm²
η_t — termination efficiency, about 0.9 for a ferrule-secured eye
Z — coefficient of utilisation (safety factor)
Assumptions and limitations
The K factors were checked against PFEIFER's EN 12385-4 tables: 252 kN for 20 mm 6×36 IWRC 1770 and 234 kN with a fibre core. A rope certificate always takes precedence.
Bending over a small sheave or pin weakens the rope. Sling ratings assume a large bend, often 25 rope diameters for a basket hitch. Reduce the efficiency for tighter bends, using the maker's D/d curve.
Chain WLLs are for one leg in a straight pull, from the EN 818-4 table (metric Grade 8) and the NACM tables (US Grade 80 and 100).
Sling angles, hitches, dynamic loads, wear, corrosion and broken wires are not included. Use the lifting sling calculator for multi-leg slings.
Worked example
A 20 mm 6×36 IWRC wire rope of grade 1770 has ferrule-secured eyes and is used as a sling. What is its safe working load?
As the runner of a ship's crane, the ILO coefficient applies instead. For this rope it works out at 5.13, so the SWL is 4.51 t.
FAQ
How do I calculate the safe working load of a wire rope?
Find the minimum breaking load from the certificate or from K d² R_r / 1 000, multiply by the termination efficiency, and divide by the safety factor.
What safety factor is used for wire rope?
5 for general lifting slings under EN 13414-1 and ASME B30.9. For ships' lifting appliances the ILO formula gives about 5.2 for small loads, falling to 3 at 160 t.
What is the difference between SWL, WLL and MBL?
MBL is the minimum breaking load. WLL, the working load limit, is the maximum load the maker certifies for a straight lift. SWL is the safe working load assigned in a given use; in many cases it equals the WLL.
Is a steel core rope stronger than a fibre core rope?
Yes. In the 6×19 and 6×36 classes the steel core rope is about 8 % stronger at the same diameter and grade (K 0.356 against 0.330), and it crushes less on a drum.
What is the WLL of a 10 mm Grade 8 chain?
3.15 t in a straight single-leg pull, by EN 818-4. Its breaking force is at least four times that.
Can I use this for mooring lines?
Not directly. Mooring lines are sized by OCIMF MEG4 from the ship design MBL; use the mooring line calculator.
Before every release the calculator must reproduce each case below. The note under each case says where the expected answer comes from: a standard, a textbook, a published table, or a hand calculation shown in full.
EN 12385-4 against PFEIFER tables: 6×36 IWRC 1770 at 8, 20 and 32 mm = 40.3, 252 and 645 kN; 1960 at 20 mm = 279 kNPFEIFER data sheet 6x36WS-WC (rev. 10/2020), according to EN 12385-4
Fibre core K = 0.330: 6×36 FC 1770 at 20 mm = 234 kN and 1960 at 10 mm = 64.7 kN; 6×19 FC 1770 at 6 mm = 21 kNPFEIFER data sheets 6x36WS-FC (rev. 5/2019) and 6x19S-FC, according to EN 12385-4
SWL of 20 mm 6×36 IWRC 1770 with a ferrule eye (0.9) and factor 5: 226.8 / 5 = 45.4 kN = 4.63 tEN 13414-1 (coefficient 5, ferrule-secured termination 0.9); hand calculation
ILO C152: the coefficient is 10⁴/(8.85 SWL + 1910): 5.00 at 10 t, 3.01 at 160 t, 3 above; a sling uses 5 up to 10 tILO C152 register form No. 4 instructions (OSHA 29 CFR 1918 Appendix I)
Overload warns; a diameter of 1 mm and a size that the grade does not have are rejectedBehaviour check: warnings and rejected inputs
Worked example of the article: the calculator reproduces 252.0 kN, 226.8 kN, 45.4 kN, 4.63 t to the digits printedThe worked example on this page, to the digits printed
Assumptions and sources
Assumptions and limits
The minimum breaking force of stranded rope is K d² R_r / 1000 kN by EN 12385-4, with K = 0.330 for fibre core and 0.356 for steel core ropes of the 6×19 and 6×36 classes, d the nominal diameter in mm and R_r the rope grade in N/mm². A manufacturer's certificate overrides it.
The termination efficiency covers the strength lost at the end fitting or over a sheave or pin: about 0.9 for a ferrule-secured eye (EN 13414-1) and lower for wedge sockets or bulldog grips. Bending a rope over a pin smaller than about 25 rope diameters cuts its strength further; use the maker's D/d curve.
The ILO coefficients (ILO Convention 152, certificate form 4) are 10⁴ / (8.85 SWL + 1 910) with SWL in tonnes: about 5 for small loads, falling to 3 at 160 t. Slings use 5 up to 10 t. National rules and class may set other values.
Chain working load limits are for a single leg in a straight pull at normal temperature, from the EN 818-4 table for metric Grade 8 and from the NACM tables for US Grade 80 and Grade 100 chain. Their minimum breaking force is at least four times the WLL.
Sling angle, hitch type, dynamic loads and wear are not included: use the lifting sling calculator for multi-leg slings and reduce for worn, kinked or corroded rope or chain.
Sources
EN 12385-4:2002+A1:2008 Steel wire ropes — Safety — Part 4: Stranded ropes for general lifting applications, Table B.1 (minimum breaking force factors); PFEIFER data sheets 6x36WS-WC and 6x36WS-FC (2019–2020)
EN 13414-1:2003+A2:2008 Steel wire rope slings — Part 1: Slings for general lifting service (coefficient 5, termination efficiency 0.9 for ferrule-secured eyes)
ILO Convention C152 (1979), Occupational Safety and Health (Dock Work), register form No. 4 instructions as reproduced in OSHA 29 CFR 1918 Appendix I: coefficient of utilisation of wire rope