Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person. Report a problem
Introduction
A decibel is a tenth of a bel, the logarithm of a power ratio. For power, dB = 10 log10(P2 / P1). For voltage or current, dB = 20 log10(V2 / V1), because power goes with the square of the voltage. Doubling the power adds 3.01 dB, and doubling the voltage adds 6.02 dB. With a fixed reference the decibel becomes an absolute level: 0 dBm is 1 mW, and 0 dBV is 1 V.
This calculator converts ratios to decibels and back, and converts absolute levels between dBm, dBW, dBV, dBµV, dBu, watts and volts across an impedance you choose. It also adds the levels of several uncorrelated sources. It is for radio, audio and electronics engineers, technicians and students working with gains, losses, signal levels and noise.
Formulas
Ratios:
L = 10 log10(P2 / P1) dB = 20 log10(V2 / V1) dB
P2 / P1 = 10^(L/10), V2 / V1 = 10^(L/20)
P — power, W; V — r.m.s. voltage, V; R — impedance, Ω
0.7746 V — the voltage of 1 mW in 600 Ω, √(0.001 × 600)
Assumptions and limitations
The 20 log form gives the same number as the power ratio only when both voltages act across the same impedance.
Voltages are r.m.s. values. A peak or peak-to-peak value must be converted first.
dBm and dBW are power levels. dBV, dBµV and dBu are voltage levels, related to power through the impedance entered.
The dBu is a voltage level and needs no 600 Ω load. It equals dBm only across 600 Ω.
The sum assumes uncorrelated sources such as separate machines or noise, whose powers add. Identical signals in phase add their voltages and can give up to 6 dB more.
Worked example
A signal generator delivers 10 dBm into a 50 Ω load. What is that in watts, volts and the other level units?
Power: P = 1 mW × 10^(10/10) = 10 mW, which is 0.0100 W.
In dBW: 10 − 30 = −20.00 dBW.
Voltage across 50 Ω: V = √(0.0100 × 50) = 0.707 V r.m.s.
In dBV: 20 log10(0.707) = −3.01 dBV.
In dBµV: −3.01 + 120 = 117.0 dBµV.
In dBu: 20 log10(0.707 / 0.7746) = −0.79 dBu.
The same 10 dBm across 600 Ω would be 2.45 V and 10 dBu, which shows why the impedance matters.
FAQ
How do I convert dBm to watts?
Divide the dBm value by 10, raise 10 to that power, and multiply by 1 mW. 30 dBm is 1 W and 20 dBm is 100 mW.
What is the difference between 10 log and 20 log?
10 log is for power ratios. 20 log is for voltage and current ratios, because power is proportional to the voltage squared.
What is the difference between dBu and dBV?
dBV is referred to 1 V and dBu to 0.7746 V. A level in dBu is 2.22 dB higher than the same level in dBV.
What does adding 3 dB mean?
Doubling the power. Two equal uncorrelated sources together are 3 dB louder than one, and ten of them are 10 dB louder.
How do I add decibel levels?
Convert each to a power ratio with 10^(L/10), add them, and take 10 log10 of the sum. 85, 82 and 79 dB make 87.4 dB.
How do I convert dBµV to dBm in a 50 Ω system?
Subtract 107. In 50 Ω, 0 dBm is 0.2236 V, which is 107.0 dBµV.
Before every release the calculator must reproduce each case below. The note under each case says where the expected answer comes from: a standard, a textbook, a published table, or a hand calculation shown in full.
A power ratio of 2 is 3.0103 dB, 10 is 10 dB; a voltage ratio of 2 is 6.0206 dB, 10 is 20 dBIEC 60027-3: L_P = 10 lg(P2/P1) dB, L_F = 20 lg(F2/F1) dB
−6 dB is a power ratio of 0.2512 and a voltage ratio of 0.5012; 0 dB is 1Inverse of the definitions: 10^(dB/10), 10^(dB/20)
0 dBm in 50 Ω is 1 mW, −30 dBW, 0.2236 V, −13.01 dBV, 107.0 dBµV; 0 dBu in 600 Ω is 0.7746 V and 0 dBmITU-R V.574-5 absolute levels; 0 dBu = √(1 mW × 600 Ω) = 0.7746 V
Round trip: 1 V r.m.s. is 0 dBV and 120 dBµV, and 120 dBµV gives 1 V backdBV re 1 V, dBµV re 1 µV
Incoherent sum: two equal levels add 3.01 dB, ten add 10 dB; 85 + 82 + 79 dB = 87.4 dBL = 10 lg Σ 10^(L_i/10) for uncorrelated sources
Invalid entries are rejected: zero ratio, text in the levels, negative watts, zero impedanceBehaviour check: warnings and rejected inputs
Worked example of the article: the calculator reproduces 0.0100 W, 0.707 V, −20.00, −3.01, 117.0, −0.79 to the digits printedThe worked example on this page, to the digits printed
Assumptions and sources
Assumptions and limits
Power ratios use 10 log10 and voltage or current ratios 20 log10; the 20 log form gives the power ratio only when both voltages act across the same impedance.
Voltages are r.m.s. values. dBm and dBW are power levels; dBV, dBµV and dBu are voltage levels, converted to power with P = V² / R across the impedance entered (50 Ω for RF, 600 Ω for traditional audio lines, 75 Ω for video and cable TV).
0 dBu is 0.7746 V r.m.s., the voltage of 1 mW in 600 Ω; dBu is a voltage level and needs no 600 Ω load, so dBu equals dBm only across 600 Ω.
Levels add as uncorrelated (incoherent) sources: their powers add, so two equal levels give 3 dB more. Coherent signals in phase add their voltages instead and can give up to 6 dB more.
Sources
IEC 60027-3:2002 Letter symbols to be used in electrical technology, Part 3: Logarithmic and related quantities, and their units (power and root-power quantities, the decibel)
ITU-R Recommendation V.574-5 (2015), Use of the decibel and the neper in telecommunications (absolute levels dBW, dBm, dB(µV))
Boylestad, Introductory Circuit Analysis, 13th ed., ch. 21 (decibels: power gain 10 log, voltage gain 20 log, dBm referred to 1 mW in 600 Ω)