Fluid mechanics and pumps glossary
28 terms from the fluids and pumps calculators, each in two or three sentences with its symbol, its unit and a typical value. Every entry links to the calculators that use it; the formula sheet has the equations.
-
Absolute roughnessεm (mm)
Also called Pipe roughness, Relative roughness, Surface roughness
Average height of the irregularities on the inside wall of a pipe or duct, divided by the bore to give the relative roughness ε/D. Typical new values are 0.0015 mm for drawn tubing and plastic, 0.045 mm for commercial steel and 0.26 mm for cast iron. Corrosion and scale raise it many times over a pipe’s life.
Pipe flow and pressure drop, Total dynamic head (TDH) calculator, Duct size calculator
-
Affinity lawsnone
Also called Pump affinity laws, Fan laws
Scaling rules for centrifugal pumps and fans run at a new speed or impeller diameter. At fixed diameter, flow varies with speed, head or pressure with speed squared and power with speed cubed, so a 10 % speed cut saves about 27 % of shaft power. They hold between similar operating points and lose accuracy for large impeller trims.
-
Bernoulli equationnone
Also called Bernoulli’s principle, Bernoulli’s equation
Energy balance along a streamline of steady, incompressible, frictionless flow: pressure head, velocity head and elevation head add to a constant, p/ρg + v²/2g + z. A head-loss term is added for real pipes. It explains the pressure drop in a venturi throat and underlies orifice, nozzle and venturi flow meters.
Bernoulli's equation and venturi, Orifice and venturi flow (ISO 5167), Nozzle flow calculator (orifice, fire nozzle and K-factor), Total dynamic head (TDH) calculator
-
Cavitationnone
Formation and violent collapse of vapour bubbles where the local liquid pressure falls to the vapour pressure, as at a pump impeller eye or a valve vena contracta. It causes noise, vibration, loss of head and pitting of metal surfaces. Pumps avoid it by keeping NPSH available above NPSH required with a margin.
-
Choked flownone
Also called Critical flow, Sonic flow
Condition in which flow through a restriction stops increasing as the downstream pressure is lowered further. In gases the throat reaches sonic velocity, at about 0.53 of the upstream absolute pressure for air; in liquids flashing or cavitation fills the vena contracta. Control valve and relief valve sizing must check for it.
Control valve Cv / Kv sizing, Relief valve sizing (API 520), Compressed air calculator: leaks, receiver, pipe drop and power
-
Colebrook equationnone
Also called Colebrook–White equation, Moody chart
Implicit formula for the Darcy friction factor of turbulent pipe flow from Reynolds number and relative roughness: 1/√f = −2 log10(ε/3.7D + 2.51/(Re√f)). It is solved by iteration, or replaced by explicit fits such as Swamee–Jain or Haaland that agree within about 1 to 2 %. The Moody chart is a plot of it.
Pipe flow and pressure drop, Total dynamic head (TDH) calculator, Duct size calculator, Reynolds number and flow regime
-
Darcy friction factorfdimensionless
Also called Friction factor, Moody friction factor, Fanning friction factor
Coefficient that sets the pressure loss of flow in a straight pipe through the Darcy–Weisbach equation. In laminar flow it equals 64/Re; in turbulent flow it depends on Reynolds number and relative roughness and usually lies between 0.01 and 0.05. The Fanning friction factor used in some texts is one quarter of it.
Pipe flow and pressure drop, Total dynamic head (TDH) calculator, Minor losses calculator (pipe fittings and valves), Duct size calculator, Reynolds number and flow regime
-
Darcy–Weisbach equationnone
Also called Darcy equation, Pipe friction loss
Head loss relation for flow in a full pipe, h_f = f (L/D) v²/2g, where f is the Darcy friction factor, L the length, D the bore and v the mean velocity. It holds for any fluid and flow regime, unlike Hazen–Williams, which applies only to water near ordinary temperatures.
Pipe flow and pressure drop, Total dynamic head (TDH) calculator, Duct size calculator, Compressed air calculator: leaks, receiver, pipe drop and power
-
Discharge coefficientCddimensionless
Also called Cd, Coefficient of discharge
Ratio of the actual flow through an orifice, nozzle or valve to the ideal flow from Bernoulli at the same pressure difference. A sharp-edged orifice plate gives about 0.60 to 0.62, a well-rounded nozzle 0.95 to 0.99 and a classical venturi 0.98 to 0.995. It accounts for the vena contracta and friction losses.
Orifice and venturi flow (ISO 5167), Nozzle flow calculator (orifice, fire nozzle and K-factor), Compressed air calculator: leaks, receiver, pipe drop and power, Relief valve sizing (API 520)
-
Dynamic viscosityμPa·s (cP)
Also called Absolute viscosity, Viscosity, Centipoise
Resistance of a fluid to shearing, the ratio of shear stress to rate of shear strain. Water at 20 °C has about 1.0 mPa·s (1 cP), air about 0.018 mPa·s and heavy fuel oil hundreds of mPa·s at its handling temperature. It falls steeply with temperature in liquids and rises slightly in gases.
cSt to SSU viscosity converter (Saybolt seconds), Orifice and venturi flow (ISO 5167), Reynolds number and flow regime, Fuel blending and heating viscosity
-
Equivalent lengthLem (ft)
Also called L/D ratio
Length of straight pipe of the same bore that causes the same head loss as a fitting or valve, equal to K D/f. In the Crane method a standard 90° elbow counts as 30 pipe diameters and a fully open gate valve as 8. Adding it to the real length lets one friction calculation cover the whole line.
Minor losses calculator (pipe fittings and valves), Total dynamic head (TDH) calculator
-
Flow coefficientCvUS gpm/√psi (Kv in m³/h/√bar)
Also called Cv, Kv, Valve flow coefficient
Valve capacity rating: the flow of water at 60 °F in US gallons per minute that passes with a pressure drop of 1 psi. The metric Kv is the flow in m³/h at a 1 bar drop, and Cv = 1.156 Kv. Liquid flow scales with the square root of pressure drop divided by specific gravity.
-
Free air deliverym³/min (cfm)
Also called FAD, Free air, Compressor capacity
Volume flow a compressor delivers, restated at the pressure, temperature and humidity of its inlet, as defined in ISO 1217. Industrial screw compressors at about 7 bar deliver roughly 0.12 to 0.18 m³/min of free air per kW of shaft power. Comparing machines rated at different reference conditions is a common error.
Compressed air calculator: leaks, receiver, pipe drop and power
-
Hazen–Williams coefficientCnone (empirical factor)
Also called C-factor, Hazen–Williams C
Empirical smoothness factor in the Hazen–Williams head loss formula for water; a higher value means a smoother pipe. Plastic and copper take about 150, cement-lined iron 140, steel in wet sprinkler systems 120 and unlined cast iron 100 or less. The formula is valid only for water near ordinary temperatures in turbulent flow.
-
Hydraulic diameterDhm
Equivalent diameter of a non-circular flow passage, four times the flow area divided by the wetted perimeter. For a full circular pipe it equals the bore and for a square duct the side length. It lets pipe friction and Reynolds number correlations be applied to ducts, channels and annuli.
Reynolds number and flow regime, Pipe flow and pressure drop
-
Hydraulic radiusRhm
Flow area divided by the wetted perimeter of an open channel or partly full pipe, the length used in Manning’s equation. A circular pipe running full or half full has R_h = D/4, and a wide shallow channel approaches its depth. It is one quarter of the hydraulic diameter.
Open-channel flow (Manning), Drain pipe size calculator (Manning), Culvert capacity and headwater calculator (HDS-5)
-
Hydrostatic pressurepPa (psi)
Also called Head pressure, Pressure at depth
Pressure exerted by a fluid at rest due to the weight of the column above a point, p = ρgh. Fresh water adds about 9.81 kPa per metre of depth (0.433 psi per foot) and sea water about 10.1 kPa per metre. It acts equally in all directions and does not depend on the shape of the container.
Hydrostatic pressure at depth, Pump NPSH and suction lift, Total dynamic head (TDH) calculator
-
Kinematic viscosityνm²/s (cSt)
Also called Centistokes, cSt
Dynamic viscosity divided by density, the property that enters the Reynolds number and that gravity-flow viscometers measure. Water at 20 °C has about 1.0 mm²/s (1 cSt) and marine gas oil 2 to 6 cSt at 40 °C. Fuel oil grades are named by it: RMG 380 is at most 380 cSt at 50 °C.
cSt to SSU viscosity converter (Saybolt seconds), Reynolds number and flow regime, Total dynamic head (TDH) calculator, Fuel blending and heating viscosity
-
Laminar flownone
Also called Streamline flow, Viscous flow
Smooth flow in which fluid moves in parallel layers without mixing between them, found in pipes below a Reynolds number of about 2 300. The velocity profile is parabolic, with the centreline at twice the mean velocity, and the friction factor is 64/Re whatever the roughness. Viscous oils in small pipes often run laminar.
Reynolds number and flow regime, Pipe flow and pressure drop
-
Net positive suction headNPSHm (ft)
Also called NPSH, NPSHa, NPSHr, NPSH3
Total absolute head at the pump suction, referred to the impeller centreline, minus the vapour pressure head of the liquid. NPSH available comes from the system; NPSH required, usually NPSH3, is where the pump loses 3 % of its head. Keep NPSHa above NPSHr by at least 0.5 to 1 m or a ratio of 1.1 to 1.3, since cavitation starts before the 3 % drop.
Pump NPSH and suction lift, Total dynamic head (TDH) calculator, Pipe flow and pressure drop
-
Pump efficiencyηpdimensionless
Also called Best efficiency point, BEP
Ratio of the hydraulic power given to the liquid, ρgQH, to the shaft power taken by the pump. Small centrifugal pumps reach about 40 to 60 % and large ones 80 to 90 % at their best efficiency point. Running far from that point lowers efficiency and raises vibration and wear.
Pump power calculator, Pump and fan affinity laws, Total dynamic head (TDH) calculator
-
Resistance coefficientKdimensionless
Also called K-factor, Minor loss coefficient, Loss coefficient
Number of velocity heads lost across a fitting, valve, entrance or exit, so that the head loss is K v²/2g. A sharp pipe entrance is about 0.5, an exit into a tank 1.0, a long-radius 90° elbow 0.2 to 0.4 and a fully open globe valve 4 to 10. The K values of a line add.
Minor losses calculator (pipe fittings and valves), Total dynamic head (TDH) calculator, Bernoulli's equation and venturi
-
Reynolds numberRedimensionless
Also called Re, Flow regime, Turbulent flow
Ratio of inertial to viscous forces in a flow, Re = ρvD/μ = vD/ν. In a pipe, flow is laminar below about 2 300, transitional up to about 4 000 and turbulent above. It sets the friction factor and must match between a model and full scale for viscous effects to scale.
Reynolds number and flow regime, Pipe flow and pressure drop, Total dynamic head (TDH) calculator, Orifice and venturi flow (ISO 5167), Duct size calculator
-
Saybolt Universal SecondsSUSs
Also called SUS, SSU, Saybolt seconds
Time in seconds for 60 mL of oil to flow through the calibrated orifice of a Saybolt Universal viscometer at a set temperature, an older US measure of kinematic viscosity. Above about 75 cSt, SUS at 100 °F is roughly 4.63 times the value in cSt. ASTM D2161 gives the full conversion.
-
Total dynamic headHm (ft)
Also called TDH, Total head, Pump head
Head a pump must add to the liquid: static lift plus the difference in surface pressure heads plus friction and fitting losses in the suction and discharge lines, with any change in velocity head. It is expressed in metres or feet of the pumped liquid, so it does not depend on density. The pump curve gives the flow at that head.
Total dynamic head (TDH) calculator, Pump power calculator, Pump and fan affinity laws, Pump NPSH and suction lift
-
Velocity headhvm (ft)
Also called Dynamic head
Kinetic energy of a flowing liquid per unit weight, expressed as a height, v²/2g. Water at 3 m/s has a velocity head of about 0.46 m. Fitting losses are counted as multiples of it, and it must be included when comparing pressures at sections of different bore.
Minor losses calculator (pipe fittings and valves), Bernoulli's equation and venturi, Total dynamic head (TDH) calculator
-
Water hammernone
Also called Hydraulic shock, Surge pressure, Joukowsky equation
Pressure surge caused when the velocity of liquid in a pipe changes quickly, as at fast valve closure or pump trip. The Joukowsky rise is Δp = ρaΔv, where the wave speed a is about 1 000 to 1 400 m/s in steel pipe, so stopping water at 1 m/s adds about 10 to 14 bar. Closing slower than 2L/a reduces the peak.
Water hammer (Joukowsky), Pipe wall thickness (ASME B31.3), Pipe flow and pressure drop
-
Weirnone
Also called V-notch weir, Sharp-crested weir, Parshall flume
Overflow barrier across an open channel whose crest shape fixes the relation between upstream head and flow, used to measure or control discharge. Flow over a rectangular sharp-crested weir varies with head to the power 1.5 and over a 90° V-notch with head to the power 2.5. Read the head upstream of the drawdown, about four times the maximum head.