Chemical and process engineering glossary
18 terms from the process and chemical calculators, each in two or three sentences with its symbol, its unit and a typical value. Every entry links to the calculators that use it; the formula sheet has the equations.
-
Antoine equationnone
An empirical three-constant correlation of a pure liquid’s vapour pressure with temperature, log10 P = A − B / (C + T). The constants are fitted to measured data and hold only over a stated temperature range, often 50 to 100 K wide. Using them outside that range is the most common source of large errors.
-
API gravity°API
Also called °API, API degrees
A petroleum scale of liquid density defined from specific gravity at 60 °F: °API = 141.5 / SG − 131.5. Water is 10 °API, light crude oils are above about 31 °API, heavy crudes below about 22 °API and diesel near 35 °API. The scale runs opposite to density, so a higher number means a lighter liquid.
Specific gravity calculator (SG, API gravity, Baumé), Density calculator (mass, volume and density)
-
Chlorine demandmg/L
Also called chlorine dose, chlorine residual
The chlorine consumed by organic matter, ammonia, iron, manganese and other reducing substances in water before any residual remains. The applied dose equals demand plus the residual wanted, so a 2.5 mg/L dose that leaves 0.5 mg/L shows a demand of 2.0 mg/L. Demand rises with contact time, temperature and contamination.
Chemical dosing calculator (feed rate, pump setting, chlorine dose)
-
Compressibility factorZdimensionless
Also called Z-factor, gas deviation factor
The ratio of a real gas’s molar volume to that of an ideal gas at the same pressure and temperature, so that PV = ZnRT. Air at ambient conditions has Z within 0.001 of 1, while natural gas at pipeline pressures typically sits between 0.8 and 0.95. It is found from charts or correlations in reduced pressure and temperature.
Gas compressibility factor Z calculator (natural gas and pure gases), Mass flow rate calculator (kg/h, m³/h, velocity, Nm³/h, SCFM), Relief valve sizing (API 520), Ideal gas law (PV = nRT)
-
Dilution factordimensionless
Also called C1V1 = C2V2
The ratio of final volume to the volume of stock taken, equal to stock concentration over final concentration: C1/C2 = V2/V1. Making 10 mL of stock up to 100 mL gives a factor of 10, and three such serial steps give 1000. Written as 1:10 it usually means one part in ten in total, not one plus ten.
Dilution calculator (C1V1 = C2V2 and serial dilution), Chemical dosing calculator (feed rate, pump setting, chlorine dose)
-
Mass balancekg/s (kg/h)
Also called material balance
An account of mass for a defined system: input minus output plus generation minus consumption equals accumulation. At steady state without reaction, total mass in equals mass out, and the same holds for each component separately. It is the first step in sizing any process; a balance that will not close usually means a missed stream or a units error.
Mass balance calculator: mixing streams (flow, concentration, temperature), Blending ratio calculator (two liquids to a target property), Dilution calculator (C1V1 = C2V2 and serial dilution), Mass flow rate calculator (kg/h, m³/h, velocity, Nm³/h, SCFM)
-
Mass fractionwdimensionless (% w/w)
Also called % w/w, weight percent
The mass of one component divided by the total mass of the mixture, often given as % w/w or, for traces, as ppm by mass. Unlike molarity it does not change with temperature, which is why commercial chemicals are sold on this basis, such as sodium hypochlorite at 10 to 15 % and sulfuric acid at 93 to 98 %.
PPM concentration converter (mg/L, % w/w, ppmv, mg/m³, mol/L), Chemical dosing calculator (feed rate, pump setting, chlorine dose), Molarity calculator (moles, mass, volume, normality), Blending ratio calculator (two liquids to a target property), Mass balance calculator: mixing streams (flow, concentration, temperature)
-
Molaritycmol/L (M)
Also called molar concentration, amount concentration, mol/L
The amount of solute in moles per litre of solution, not per litre of solvent. It equals the mass of solute divided by its molar mass and by the solution volume, so 58.44 g of sodium chloride made up to 1 L gives 1 mol/L. It shifts slightly with temperature because the solution volume does.
Molarity calculator (moles, mass, volume, normality), Dilution calculator (C1V1 = C2V2 and serial dilution), PPM concentration converter (mg/L, % w/w, ppmv, mg/m³, mol/L)
-
Normal cubic metreNm³
Also called Nm³/h, standard cubic metre, SCFM
A quantity of gas that would occupy one cubic metre at reference conditions of 0 °C and 101.325 kPa, so it measures amount of gas rather than actual volume. One Nm³ holds about 44.6 mol, while a US standard cubic foot at 60 °F and 14.696 psia holds about 1.195 mol. Always state the reference, as several are in use.
Mass flow rate calculator (kg/h, m³/h, velocity, Nm³/h, SCFM), Compressed air calculator: leaks, receiver, pipe drop and power, Gas compressibility factor Z calculator (natural gas and pure gases)
-
NormalityNeq/L
Also called equivalent concentration
The number of equivalents of solute per litre of solution, equal to molarity times the equivalents per mole for the reaction considered. A 1 mol/L sulfuric acid solution is 2 N in acid-base reactions because each molecule gives two protons. IUPAC discourages it because the value depends on the reaction, yet titration methods still use it.
-
OverpressurekPa (% of set pressure)
Also called accumulation, allowable overpressure
The pressure rise above a relief valve’s set pressure at which it passes its rated flow, usually given as a percentage of set pressure. API 520 sizes single valves at 10 %, multiple valves at 16 % and fire cases at 21 %. Accumulation is the corresponding rise above the protected vessel’s maximum allowable working pressure.
-
Parts per milliondimensionless (mg/kg, ppmv)
Also called ppm, ppmv, ppb, mg/L
A ratio of one part in a million, by mass for liquids and solids (mg/kg) and by volume or mole for gases (ppmv). In dilute water 1 mg/L is close to 1 ppm by mass; in air at 25 °C and 1 atm, mg/m³ = ppmv × molar mass / 24.45. Always state the basis.
PPM concentration converter (mg/L, % w/w, ppmv, mg/m³, mol/L), Chemical dosing calculator (feed rate, pump setting, chlorine dose), Mass balance calculator: mixing streams (flow, concentration, temperature)
-
Reduced pressurePrdimensionless
Also called reduced temperature, pseudo-reduced pressure, corresponding states
The ratio of a gas’s absolute pressure to its critical pressure, P/P_c; reduced temperature T/T_c is defined the same way with absolute temperatures. By the principle of corresponding states, gases at the same reduced conditions have nearly the same compressibility factor. For mixtures, pseudo-critical values from Kay’s rule or a gravity correlation replace the true critical point.
Gas compressibility factor Z calculator (natural gas and pure gases)
-
Reflux ratioRdimensionless
Also called minimum reflux ratio, R_min, L/D
The ratio of liquid returned to the top of a distillation column to the distillate drawn off, L/D. The minimum reflux ratio, found by the Underwood method, would need infinitely many stages, so designs usually run at 1.1 to 1.5 times the minimum. Higher reflux means fewer trays but larger reboiler and condenser duties.
-
Relative volatilityαdimensionless
Also called alpha
The ratio of the equilibrium K-values, vapour over liquid mole fraction, of two components, light over heavy. Above about 2 distillation is easy; below about 1.1 it needs very many stages and high reflux, and at 1.0, as at an azeotrope, no separation is possible. For ideal mixtures it equals the ratio of the pure-component vapour pressures.
Distillation stages calculator (Fenske–Underwood–Gilliland), Vapour pressure calculator (Antoine equation)
-
Set pressurePsetkPa gauge (psig)
Also called relief valve set point, opening pressure
The inlet gauge pressure at which a pressure relief valve is adjusted to begin opening under service conditions. It is normally no higher than the maximum allowable working pressure of the protected equipment, and operating pressure is kept below about 90 % of it, or up to about 95 % with pilot-operated valves, to avoid simmer and seat leakage.
-
Specific gravitySGdimensionless
Also called relative density, SG
The ratio of a substance’s density to that of a reference: water for liquids, usually at 60 °F or 4 °C, and air at the same temperature and pressure for gases. Petrol is about 0.74, seawater 1.025 and 98 % sulfuric acid 1.84. Quoting it without the reference temperatures can shift the result in the third decimal.
Specific gravity calculator (SG, API gravity, Baumé), Density calculator (mass, volume and density), Gas compressibility factor Z calculator (natural gas and pure gases), Relief valve sizing (API 520)
-
Vapour pressurepvkPa (psia)
Also called saturation pressure, vapor pressure
The pressure of a vapour in equilibrium with its liquid at a given temperature; a liquid boils when its vapour pressure reaches the surrounding pressure. Water has 2.34 kPa at 20 °C and 101.325 kPa at 100 °C. It rises steeply with temperature and governs NPSH available, flashing and evaporation losses from tanks.
Vapour pressure calculator (Antoine equation), Pump NPSH and suction lift, Steam table calculator (IAPWS-IF97)
Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person.