Energy and renewables practice problems
10 multiple-choice problems in the style of the FE and PE engineering exams. Pick an answer to check it, then open the worked solution. Every answer is recomputed by the energy and renewables calculator that solves it, and the solution opens that calculator with the problem's numbers filled in.
-
Charge time of a lead-acid battery from a fixed-current charger
A 12 V, 120 Ah AGM battery on a boat is at 35 % state of charge. A 15 A charger brings it to 90 %. The charge efficiency of the battery is 85 %, so more ampere-hours go in than come out. Treating the charger current as constant, how long does the charge take?
Show the answer and worked solution
Answer: B, 5.18 h
- Charge to put back: 120 × (0.90 − 0.35) = 66 Ah.
- From the charger: 66 / 0.85 = 77.6 Ah.
- Time: t = 77.6 / 15 = 5.18 h.
- The traps: 4.40 h ignores the charge efficiency, 3.74 h multiplies by the efficiency instead of dividing, and 9.41 h recharges the whole 120 Ah instead of the 55 % that is missing.
Check every step: Battery charge time, opened with this problem’s numbers
-
Yearly running cost of a thermostat-controlled heater
A 2 kW electric heater warms a site office for 6 hours a day, 5 days a week, all year. Its thermostat keeps the element on for 65 % of that time. Electricity costs €0.30 per kWh. Taking a year as 365.25 days, what does the heater cost to run per year?
Show the answer and worked solution
Answer: C, €610
- Energy per day of use: E = P × t × duty = 2 × 6 × 0.65 = 7.8 kWh.
- Days of use per year: 365.25 × 5 / 7 = 260.9 days, so the energy is 7.8 × 260.9 = 2035 kWh.
- Cost: 2035 × 0.30 = €610 per year.
- The traps: €855 counts 7 days a week, €939 ignores the thermostat duty cycle, and €1 315 makes both mistakes.
Check every step: Electricity cost and energy use, opened with this problem’s numbers
-
EV charging time on a wallbox limited by the onboard charger
An electric car with a 64 kWh usable battery is plugged into a 22 kW three-phase wallbox at 10 % state of charge and charged to 80 %. The car's onboard charger accepts at most 11 kW AC. Grid-to-battery charging efficiency is 90 %. How long does the charge take?
Show the answer and worked solution
Answer: D, 4.53 h
- Energy into the battery: 64 × (0.80 − 0.10) = 44.8 kWh.
- Energy from the grid: 44.8 / 0.90 = 49.8 kWh.
- The charging power is the lower of the wallbox and the onboard charger, 11 kW, so t = 49.8 / 11 = 4.53 h.
- The traps: 2.26 h uses the 22 kW wallbox rating, 4.07 h ignores the charging losses, and 3.67 h multiplies by the efficiency instead of dividing.
Check every step: EV charging time and cost calculator, opened with this problem’s numbers
-
Yearly saving of a heat pump against a gas boiler
A house needs 14 000 kWh of heat per year. The present gas boiler has a seasonal efficiency of 90 % and gas costs €0.09 per kWh. A heat pump with a seasonal COP of 3.2 would run on electricity at €0.24 per kWh. How much would the heat pump save per year in running cost?
Show the answer and worked solution
Answer: A, €350
- Heat pump: electricity = 14 000 / 3.2 = 4375 kWh, cost = 4375 × 0.24 = €1 050.
- Boiler: gas burned = 14 000 / 0.90 = 15 556 kWh, cost = 15 556 × 0.09 = €1 400.
- Saving: 1 400 − 1 050 = €350 per year.
- The traps: €210 forgets the boiler efficiency (gas = heat), €84 multiplies the heat by the boiler efficiency instead of dividing, and €1 050 is the heat pump running cost, not the saving.
Check every step: Heat pump vs gas boiler running cost calculator, opened with this problem’s numbers
-
Watt-hour rating of a lithium-ion battery pack
A laptop battery pack has four lithium-ion cells in series, each 3.6 V nominal and 4.2 V when full. The pack is rated 6400 mAh at its 14.4 V nominal voltage. An airline asks for the energy rating in watt-hours. What is it?
Show the answer and worked solution
Answer: B, 92.2 Wh
- Energy: E = Q × V = 6.4 Ah × 14.4 V = 92.2 Wh, below the 100 Wh limit for carry-on batteries.
- The traps: 23.0 Wh uses the 3.6 V of one cell, 107.5 Wh uses the full-charge voltage 4 × 4.2 = 16.8 V instead of the nominal voltage, and 368.6 Wh multiplies the capacity by four cells as well, although cells in series share the same ampere-hours.
Check every step: mAh to Wh battery capacity, opened with this problem’s numbers
-
Electrical output of a micro-hydro scheme
A farm micro-hydro scheme takes 80 L/s of water (density 1000 kg/m³) from a stream with a gross head of 35 m. Friction in the penstock takes 10 % of the gross head. The turbine, drive and generator together have a water-to-wire efficiency of 65 %. What electrical power does the scheme deliver?
Show the answer and worked solution
Answer: C, 16.1 kW
- Net head: H_n = 35 × (1 − 0.10) = 31.5 m.
- Electrical output: P = η ρ g Q H_n = 0.65 × 1000 × 9.81 × 0.080 × 31.5 = 16.1 kW.
- The traps: 17.9 kW uses the gross head, 24.7 kW forgets the efficiency (it is the hydraulic power at the net head), and 27.5 kW is the power of the gross head with no losses at all.
Check every step: Micro-hydro power calculator, opened with this problem’s numbers
-
Battery capacity for an off-grid cabin
An off-grid cabin uses 4.2 kWh of AC energy per day through an inverter with 92 % efficiency. The 48 V lithium iron phosphate bank must cover 2 days without sun and may be discharged to 80 % depth of discharge. Ignore temperature derating and ageing margin. What capacity in ampere-hours at 48 V does the bank need?
Show the answer and worked solution
Answer: D, 238 Ah
- Energy the bank must deliver: 4.2 × 2 / 0.92 = 9.13 kWh.
- Nominal capacity at 80 % depth of discharge: 9.13 / 0.80 = 11.4 kWh.
- At 48 V: 11 413 / 48 = 238 Ah.
- The traps: 219 Ah forgets the inverter losses, 190 Ah forgets the depth of discharge, and 951 Ah divides by the 12 V of one battery instead of the 48 V bank voltage.
Check every step: Solar battery bank calculator, opened with this problem’s numbers
-
Number of solar panels to cover a household's use
A household uses 7800 kWh of electricity per year and wants a rooftop PV system to cover all of it. The site averages 4.2 peak sun hours per day over the year, and system losses (inverter, wiring, temperature, soiling) are 14 %. The panels are rated 430 W each. How many panels are needed?
Show the answer and worked solution
Answer: A, 14 panels
- Specific yield: 4.2 × 365 × (1 − 0.14) = 1318 kWh per kW per year.
- System size: 7800 / 1318 = 5.92 kW.
- Panels: 5916 / 430 = 13.8, rounded up to 14 panels.
- The traps: 12 panels ignores the system losses, 13 panels rounds down and falls short of the target, and 11 panels multiplies the use by (1 − losses) instead of dividing.
Check every step: Solar panel calculator: how many panels do I need?, opened with this problem’s numbers
-
Simple payback of a rooftop solar system
A 6.4 kW rooftop solar system costs €12 000 installed, and a 30 % grant reduces the cost. The site yields 1150 kWh per kW per year. The household uses 60 % of the output itself, saving €0.30 per kWh, and exports the rest at €0.06 per kWh. There are no running costs. What is the simple payback period?
Show the answer and worked solution
Answer: B, 5.59 years
- Net cost: 12 000 × (1 − 0.30) = €8 400.
- First-year production: 6.4 × 1150 = 7360 kWh. Saving: 7360 × (0.60 × 0.30 + 0.40 × 0.06) = 7360 × 0.204 = €1 501.
- Simple payback: 8 400 / 1 501 = 5.59 years.
- The traps: 7.99 years forgets the grant, 3.80 years values every kWh at the import price, and 19.02 years values every kWh at the export price.
Check every step: Solar panel payback calculator, opened with this problem’s numbers
-
Power of a small wind turbine at one wind speed
A small wind turbine has a rotor diameter of 5 m and a power coefficient Cp of 0.38 (wind to electricity). It reaches its rated output at 11 m/s. The air density at the site is 1.20 kg/m³. What electrical power does the turbine produce in a steady wind of 8 m/s?
Show the answer and worked solution
Answer: C, 2.29 kW
- Swept area: A = π D² / 4 = π × 5² / 4 = 19.6 m².
- Power: P = ½ ρ A v³ Cp = 0.5 × 1.20 × 19.6 × 8³ × 0.38 = 2.29 kW (below the rated speed, so no limit applies).
- The traps: 6.03 kW is the power in the wind without Cp, 9.17 kW uses π D² (the radius taken as the diameter), and 0.29 kW uses v² instead of v³.
Check every step: Wind turbine power calculator, opened with this problem’s numbers
Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person.