Allowable bearing pressureqakPa (psf)
Also called allowable bearing capacity, safe bearing pressure, presumed bearing value
The pressure a foundation may apply to the ground with an adequate margin against shear failure and with acceptable settlement. It is often the ultimate bearing capacity divided by 2.5 to 3; presumed values in BS 8004 run from about 75 to 150 kPa for firm clay to 200 to 600 kPa for medium dense gravel.
Footing size calculator, Soil bearing capacity calculator (Terzaghi and Eurocode 7), Concrete footing calculator, Crane outrigger pad bearing pressure
-
Angle of internal frictionφ′° (degrees)
Also called friction angle, angle of shearing resistance, phi
The soil strength parameter that defines how shear strength grows with effective normal stress, through τ = c′ + σ′ tan φ′. Loose sand is about 28 to 32°, dense sand and gravel 35 to 45°, and clays in drained loading about 20 to 30°. It drives bearing capacity, earth pressure and pile shaft friction.
Soil bearing capacity calculator (Terzaghi and Eurocode 7), Retaining wall earth pressure calculator (Rankine), Pile capacity calculator (driven and bored piles)
-
Average end area methodnone
Also called end area method, cut and fill volume
An earthwork volume estimate that multiplies the distance between two cross-sections by the mean of their areas, V = L (A1 + A2) / 2. It overestimates volume where sections change shape sharply; the prismoidal formula, V = L (A1 + 4 Am + A2) / 6 with Am the area midway, is more exact.
Earthwork cut and fill volumes, Trench and excavation volume calculator
-
Characteristic compressive strengthfckMPa (psi)
Also called concrete strength, f′c, strength class, C30/37
The compressive strength of concrete below which no more than 5 % of test results are expected to fall, measured at 28 days on cylinders or cubes. Strength class C30/37 means 30 MPa on cylinders and 37 MPa on cubes; US practice specifies f′c, such as 4000 psi (27.6 MPa). Higher strength generally needs a lower water–cement ratio.
Column base plate calculator (AISC Design Guide 1), Material properties table (steel, aluminium, plastics)
-
Compass rulenone
Also called Bowditch rule, Bowditch adjustment, traverse adjustment
A method of adjusting a closed traverse that distributes the misclosure in latitude and departure to each leg in proportion to its length. The precision ratio, linear misclosure divided by the traverse perimeter, is commonly required to be 1:5000 or better for engineering work. Angular misclosure is balanced before the rule is applied.
Closed traverse calculator (compass rule), Polygon area from coordinates (shoelace method)
-
Concrete covercnommm (in)
Also called cover, nominal cover, clear cover
The distance from the concrete surface to the nearest reinforcement, including links and stirrups, which protects the steel from corrosion and fire and allows bond. Typical values are 25 to 40 mm inside buildings, 40 to 50 mm outdoors and 75 mm (3 in) for concrete cast against earth, as ACI 318 requires.
Rebar weight and quantity calculator, Concrete volume and rebar weight, Concrete footing calculator, Concrete slab calculator
-
Consolidation settlementscmm (in)
Also called primary consolidation, clay settlement, compression index
Settlement of a saturated clay as pore water slowly drains out under a sustained load, often over years. For normally consolidated clay it is Cc H / (1 + e0) × log10(σ′f / σ′0), with compression index Cc typically 0.1 to 0.5; time follows from the coefficient of consolidation and the square of the drainage path.
-
Critical depthycm (ft)
The flow depth at which specific energy is a minimum for a given discharge and the Froude number equals 1. In a rectangular channel y_c = (q² / g)^(1/3), with q the flow per unit width; deeper flow is subcritical and shallower flow supercritical. Weirs and flumes measure flow because depth passes through critical at a control.
Culvert capacity and headwater calculator (HDS-5), Weir and flume flow calculator, Open-channel flow (Manning)
-
Earth pressure coefficientKadimensionless
Also called Rankine coefficient, active earth pressure, K0, Kp
The ratio of horizontal to vertical effective stress in soil against a wall. With Rankine theory the active value is K_a = (1 − sin φ′) / (1 + sin φ′), about 0.33 for φ′ = 30°; at rest K_0 ≈ 1 − sin φ′ ≈ 0.5 and passive K_p = 1 / K_a ≈ 3.0.
-
Effective stressσ′kPa (psf)
Also called Terzaghi principle, intergranular stress
Total stress minus pore water pressure, the part of the stress carried by the soil skeleton, which controls strength and compression. Below the water table it grows by the submerged unit weight, about 8 to 11 kN/m³ per metre of depth instead of 18 to 21. Lowering groundwater raises effective stress and can cause settlement.
Consolidation settlement calculator (clay layer), Pile capacity calculator (driven and bored piles), Soil bearing capacity calculator (Terzaghi and Eurocode 7)
-
Hot mix asphaltnone
Also called HMA, asphalt concrete, blacktop
A paving material of graded aggregate bound with about 4 to 7 % bitumen by mass, mixed and laid hot at roughly 140 to 160 °C and compacted with rollers. Compacted density is about 2.3 to 2.4 t/m³ (145 lb/ft³, close to 2 short tons per cubic yard), used to convert area and thickness to tonnes.
-
Inlet controlnone
Also called outlet control, culvert headwater
A culvert flow condition in which the entrance shape, edge and headwater depth alone set the capacity, with the barrel flowing part full. Under outlet control the barrel roughness, length, slope and tailwater also matter; FHWA HDS-5 computes the headwater for both and the higher value governs.
-
Manning’s roughness coefficientns/m^(1/3)
Also called Manning’s n, Manning n, roughness coefficient
An empirical coefficient for boundary roughness in Manning’s equation, V = (1/n) R^(2/3) S^(1/2) in SI units. Concrete pipe is about 0.013, PVC 0.009 to 0.011, clean earth channels 0.022 to 0.030 and natural streams 0.03 to 0.05 or more. In US units the equation carries a factor of 1.49.
Open-channel flow (Manning), Drain pipe size calculator (Manning), Culvert capacity and headwater calculator (HDS-5)
-
Percent grade% (dimensionless)
Also called slope, gradient, grade, rise over run
Rise divided by horizontal run, multiplied by 100. A 45° slope is 100 %, a 1:12 accessibility ramp 8.33 %, and gravity drains commonly fall at 1 to 2 %. Roof pitch in US practice is rise per 12 of run, so 6:12 equals 50 % or 26.6°.
Slope calculator: percent, degrees, ratio and pitch, Roof pitch calculator: rafters, area and shingles, Drain pipe size calculator (Manning), Stair calculator: risers, treads and stringer, Vertical curve calculator (crest and sag)
-
Proctor compaction testnone
Also called Proctor test, standard Proctor, modified Proctor, maximum dry density, optimum moisture content
A laboratory test that compacts soil in a mould at several moisture contents with a fixed energy to find the maximum dry density and the optimum moisture content. The standard test (ASTM D698) applies about 600 kN·m/m³ and the modified test (ASTM D1557) about 2700 kN·m/m³, giving higher density at lower moisture.
-
Rational methodnone
Also called Q = CiA, rational formula
A peak runoff formula, Q = C i A, with C the runoff coefficient, i the rainfall intensity for a storm lasting the time of concentration and A the area. In SI, Q (m³/s) = C i A / 360 with i in mm/h and A in hectares. It suits catchments up to about 80 ha (200 acres).
Rational-method runoff, Drain pipe size calculator (Manning), Culvert capacity and headwater calculator (HDS-5)
-
Relative compactionRC%
Also called degree of compaction, percent compaction
The field dry density of compacted soil divided by the maximum dry density from the laboratory Proctor test, in percent. Specifications commonly ask for 95 % of standard or modified Proctor under structures and pavements and 90 % for general fill. It is checked with sand cone or nuclear density gauge tests.
-
Runoff coefficientCdimensionless
Also called C factor, rational C
The share of rainfall that leaves a surface as direct runoff, used in the rational method. Roofs and asphalt are about 0.75 to 0.95, parks 0.10 to 0.25 and lawns on sandy soil 0.05 to 0.20. Mixed catchments use an area-weighted value.
Rational-method runoff, Drain pipe size calculator (Manning)
-
Shaft frictionQskN (kip)
Also called skin friction, side resistance, shaft resistance
The part of a pile’s axial capacity carried by shear between the pile shaft and the surrounding soil, summed over the soil layers. In clay the unit value is α c_u with α about 0.5 to 1.0, and in sand β σ′v. Ultimate capacity adds end bearing at the tip: Q_ult = Q_s + Q_b.
-
Shoelace formulam² (ft²)
Also called coordinate method, Gauss area formula, surveyor’s formula
A method that finds the area of a polygon from the coordinates of its vertices taken in order: half the absolute value of the sum of x_i y_(i+1) − x_(i+1) y_i around the boundary. It works for any simple polygon but gives wrong results if the boundary crosses itself.
Polygon area from coordinates (shoelace method), Closed traverse calculator (compass rule)
-
Swell factor% (dimensionless)
Also called bulking factor, bulking, shrinkage factor, loose volume
The ratio of loose volume after excavation to in-situ bank volume, usually quoted as a percentage gain. Sand and gravel swell about 10 to 15 %, common earth 20 to 30 %, clay 30 to 40 % and blasted rock 50 to 70 %. Compacted fill occupies less than bank volume, so earthwork balances also need a shrinkage factor.
Earthwork cut and fill volumes, Trench and excavation volume calculator, Gravel calculator: cubic yards and tons
-
Time of concentrationtcmin
Also called Tc, concentration time
The time runoff takes to travel from the hydraulically most distant point of a catchment to the outlet. The rational method uses a storm of this duration because it gives the peak flow; small urban sites often use a minimum of 5 to 10 minutes, and formulas such as Kirpich estimate it for rural catchments.
-
Ultimate bearing capacityqultkPa (psf)
Also called bearing capacity, Terzaghi bearing capacity
The foundation pressure at which the supporting soil fails in shear. Terzaghi’s strip footing equation is q_ult = c N_c + q N_q + 0.5 γ B N_γ, with bearing capacity factors that rise steeply with friction angle; on undrained clay the Prandtl solution gives about 5.14 c_u plus the overburden pressure.
Soil bearing capacity calculator (Terzaghi and Eurocode 7), Footing size calculator, Concrete footing calculator
-
Undrained shear strengthcukPa (psf)
Also called undrained cohesion, s_u
The shear strength of a saturated clay loaded too fast for pore water to drain, used for short-term stability of foundations, slopes and excavations. Soft clay is typically 20 to 40 kPa, firm clay 40 to 75 kPa and stiff clay 75 to 150 kPa.
Soil bearing capacity calculator (Terzaghi and Eurocode 7), Pile capacity calculator (driven and bored piles)
-
Universal Transverse Mercatornone
Also called UTM, UTM zone, UTM coordinates
A grid coordinate system that divides the Earth between 80°S and 84°N into 60 zones, each 6° of longitude wide and drawn on a transverse Mercator projection with a scale factor of 0.9996 on the central meridian. Eastings carry a false origin of 500 000 m, and southern hemisphere northings one of 10 000 000 m.
Latitude/longitude to UTM converter (WGS84), Polygon area from coordinates (shoelace method)
-
Vertical curvenone
Also called crest curve, sag curve, K value
A parabolic curve joining two grades in a road or rail profile, giving a constant rate of change of grade. Its length is L = K A, with A the algebraic grade difference in percent and K set by sight distance: AASHTO gives K = 52 for crests and 45 for sags at 100 km/h.
Vertical curve calculator (crest and sag), Slope calculator: percent, degrees, ratio and pitch
-
Void ratioedimensionless
Also called voids ratio, porosity
The volume of voids in a soil divided by the volume of solids. Dense sand is about 0.4 to 0.6, loose sand 0.7 to 0.9 and soft clays 1 to 2 or more; porosity is n = e / (1 + e). Its decrease under load produces consolidation settlement.
Soil compaction calculator (Proctor relative compaction), Consolidation settlement calculator (clay layer)
-
Weir discharge coefficientCddimensionless
Also called weir coefficient, C_w, Francis formula
An empirical factor that scales the theoretical flow over a weir, Q = C_d (2/3) √(2g) b H^(3/2). A sharp-crested rectangular weir has C_d of about 0.62, close to Q = 1.84 b H^(3/2) in SI or 3.33 L H^1.5 in US units (Francis). The head H is measured upstream at 4 to 5 times the maximum head.