Water heating time calculator (tank, element, gas or heat pump)

Time to heat a water tank with an electric element, gas burner or heat pump, with standing loss, energy, cost and recovery rate in L/h or gal/h.

Units

Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person. Report a problem

Introduction

How long does a water heater take to heat up? Divide the heat the water needs, mass times specific heat times temperature rise, by the heater's useful output. A 50 gallon tank heated from 50 to 120 °F needs 8.55 kWh, so a 4.5 kW element takes just under two hours.

This calculator gives the heating time for an electric element, a gas or oil burner, or a heat pump. It includes the heat the tank loses to the room while it heats, as an exponential approach to the highest temperature the heater can hold. It also gives the energy drawn, the cost of one heat-up and the recovery rate in gallons or litres per hour. It is for homeowners, plumbers, and engineers sizing domestic and process hot water.

Formulas

Heat into the water and useful heater output:

Q = m × c × (T1 − T0),   m = ρ V
P_heat = η × P (element, burner)   or   COP × P (heat pump)

Heating time without and with standing loss:

t = Q / P_heat                                   (UA = 0)
t = τ × ln[(T_eq − T0) / (T_eq − T1)]
τ = m c / UA,   T_eq = T_room + P_heat / UA

Energy drawn and recovery rate:

E = P × t
Recovery = P_heat / (ρ c ΔT_rise)
  • V — tank volume; ρ = 999 kg/m³; c = 4 186 J/(kg·K), or 1 Btu/(lb·°F)
  • T0, T1 — starting and target water temperatures; T_room — air around the tank
  • η — element or burner efficiency; COP — heat pump coefficient of performance
  • UA — standing loss coefficient of the tank in W/K; τ — its time constant

Assumptions and limitations

  • The water is treated as fully mixed. A real tank stratifies, so hot water reaches the top outlet well before the whole tank is at the set point.
  • The efficiency and the COP are constant. A heat pump's COP falls as the water gets hotter, so its last few degrees take longer than calculated.
  • The standing loss uses a constant UA. A tank that loses S watts when 45 K above the room has UA = S / 45.
  • The recovery rate uses the full heater output, as makers quote it. The standing loss is not deducted.
  • Water properties are taken at about 15 °C. They change by less than 2 % between 10 and 60 °C.

Worked example

A 50 US gallon electric water heater has a 4.5 kW element. The water comes in at 50 °F and the thermostat is set to 120 °F. The tank loses 2 W/K to a 68 °F room. Electricity costs 0.15 per kWh.

  1. Mass of water: 999 × 0.1893 m³ = 189.1 kg.
  2. Temperature rise: 120 − 50 = 70 °F, or 38.9 K.
  3. Heat needed: 189.1 × 4 186 × 38.9 = 30.78 MJ, or 8.55 kWh.
  4. Time constant: 189.1 × 4 186 / 2 = 395 700 s, about 110 h. T_eq = 20 + 4 500 / 2 = 2 270 °C, far above the target.
  5. Time: 395 700 × ln[(2 270 − 10) / (2 270 − 48.9)] = 6 869 s, or 114.5 min.
  6. Energy drawn: 4.5 kW × 6 869 s = 8.59 kWh, which costs 1.29.
  7. Recovery at a 90 °F rise: 4 500 / (999 × 4 186 × 50) × 3 600 = 0.0775 m³/h, or 20.5 US gal per hour (77 litres).

The standing loss adds only 0.5 minutes here. It matters far more over a whole day than during one heat-up.

Common cases

Time to heat a full tank from 10 °C (50 °F) to 49 °C (120 °F), with a standing loss of 2 W/K to a 20 °C room. Gas burners are taken at 80 % recovery efficiency and the heat pump at a COP of 3. Hot water reaches the top outlet sooner than the whole tank.

CaseHeaterTank (US gal)Input power (kW)Time (min)Energy drawn (kWh)
30 gal electric, 3.8 kW elementElectric element303.881.4085.1559
40 gal electric, 4.5 kW elementElectric element404.591.5886.8691
50 gal electric, 4.5 kW elementElectric element504.5114.488.5863
80 gal electric, 4.5 kW elementElectric element804.5183.1813.738
40 gal gas, 40 000 Btu/h burnerGas or oil burner4011.72343.858.5674
50 gal gas, 40 000 Btu/h burnerGas or oil burner5011.72354.81210.709
50 gal heat pump, 0.5 kW electrical inputHeat pump500.5346.452.887
80 L cylinder, 2 kW immersionElectric element21.1342109.473.6488
150 L cylinder, 3 kW immersionElectric element39.6263136.396.8194
10 L under-sink heater, 2 kWElectric element2.6417213.6830.4561

Every row is worked out by this calculator each time the site is built, and checked for impossible values. Open a case to load its inputs.

Common mistakes

  • Adding both elements of a two-element tank. Most domestic electric tanks with an upper and a lower element are wired so that only one heats at a time; check the wiring label. Entering 9 kW for a tank with two 4.5 kW elements gives 57 minutes for the example instead of 114.5.
  • Taking the gas input rating as the heat into the water. The Btu/h on the label is the fuel input. At 80 % recovery efficiency a 40 000 Btu/h burner heats 50 US gallons from 50 to 120 °F in 54.8 minutes; assuming 100 % gives 43.8 minutes.
  • Entering a heat pump's heat output as its input. The power field takes the electrical input, which the calculator multiplies by the COP. A 0.5 kW input at a COP of 3 heats the 50 gallon tank in 346 minutes; entering the 1.5 kW heat output instead gives 114.5 minutes.
  • Reading a Fahrenheit rise as kelvin. US recovery ratings use a 90 °F rise, which is 50 K. A 4.5 kW element recovers 20.5 gallons per hour at that rise; entering 90 K gives 11.4 gallons per hour.
  • Setting a heat pump tank above about 65 °C. Most heat pumps cannot reach it without the backup element, which heats at a COP of 1, and the COP falls as the water gets hotter. Both the time and the energy are then higher than calculated.

FAQ

How long does a 50 gallon water heater take to heat?

From 50 to 120 °F, about 114 minutes with a 4.5 kW element. A 40 000 Btu/h gas burner at 80 % efficiency does it in about 55 minutes.

What is the recovery rate of a water heater?

The volume it can heat through a stated rise in one hour, usually 90 °F in the US. A 4.5 kW element recovers about 20.5 gallons per hour at that rise.

How much heat does a tank lose standing still?

UA times the temperature difference. A tank with UA = 2 W/K at 120 °F in a 68 °F room loses 58 W, about 1.4 kWh a day.

Why does a heat pump water heater heat slowly?

Its heat output is the COP times a small electrical input. The time depends only on that heat output, while the energy drawn is only a third of an element's at a COP of 3.

How do I convert kW to Btu/h?

Multiply by 3 412. A 4.5 kW element gives 15 354 Btu/h, and a therm of gas is 29.31 kWh.

Why does my tank deliver hot water before it has fully heated?

Hot water rises and collects at the top, where the outlet is. The calculator assumes a fully mixed tank, so it gives the time for the whole volume.

Related calculators

What this calculator is checked against

Before every release the calculator must reproduce each case below. The note under each case says where the expected answer comes from: a standard, a textbook, a published table, or a hand calculation shown in full.

  1. Recovery at 90 °F rise: 4.5 kW element 20.5 gal/h; 40 000 Btu/h gas at 76 % 40.5 gal/hWater heater recovery rule gph = Btu/h × η / (8.34 lb/gal × 1 Btu/(lb·°F) × ΔT) (ASHRAE HVAC Applications, Service Water Heating); hand calculation
  2. No standing loss: 50 US gal from 50 to 120 °F with 4.5 kW takes m c ΔT / P = 30.78 MJ / 4.5 kW = 114.0 minQ = m c ΔT; t = Q / P (hand calculation)
  3. With UA the exponential solution matches a step-by-step integration of m c dT/dt = P − UA (T − T_room)Lumped energy balance (Incropera Section 5.3) integrated numerically with 1 s steps
  4. A heat pump with COP 3 heats three times as fast and draws a third of the energy of the same electrical input as an elementP_heat = COP × P_electric (hand calculation)
  5. A target above T_room + P/UA is never reached (null time and a warning); a target below the start is rejectedBehaviour check: warnings and rejected inputs
  6. Worked example of the article: the calculator reproduces 8.55 kWh, 114.5 min, 8.59 kWh, 20.5, 77 to the digits printedThe worked example on this page, to the digits printed

Assumptions and sources

Assumptions and limits

  • The tank is fully mixed: one water temperature throughout. A real tank stratifies, so hot water is available at the top well before the whole tank reaches the set point.
  • Water has a density of 999 kg/m³ (8.34 lb per US gallon) and a specific heat of 4 186 J/(kg·K), i.e. 1 Btu/(lb·°F); both change by less than 2 % between 10 and 60 °C.
  • Heat into the water is the input power times the efficiency (electric element 98 to 100 %, gas burner about 70 to 85 % recovery efficiency) or times the coefficient of performance for a heat pump. The COP is held constant, though it falls as the tank gets hotter.
  • The standing loss is UA × (T − T_room) with a constant UA, so the temperature approaches T_room + P/UA exponentially. A tank losing S watts at 45 K above the room has UA = S / 45.
  • The recovery rate is the volume heated through the given rise per hour with the full heater output, as manufacturers quote it; the standing loss is not deducted.

Sources

  • ASHRAE Handbook — HVAC Applications, chapter Service Water Heating (heater input, recovery efficiency and recovery rate)
  • US DOE 10 CFR Part 430, Subpart B, Appendix E: uniform test method for water heaters (recovery efficiency, standby loss coefficient UA)
  • F. P. Incropera et al., Fundamentals of Heat and Mass Transfer, 7th ed., Section 5.3 (energy balance of a lumped body with heat generation and convection)