Structural engineering glossary
23 terms from the structural calculators, each in two or three sentences with its symbol, its unit and a typical value. Every entry links to the calculators that use it; the formula sheet has the equations.
-
Basic wind speedvbm/s (mph)
Also called design wind speed, v_b,0, V
The reference wind speed at 10 m above open flat terrain from which design wind pressures are derived. Eurocode EN 1991-1-4 uses a 10-minute mean with a 50-year return period, typically 22 to 30 m/s; ASCE 7 uses a 3-second gust with a 300 to 3000 year return period by risk category, so its values are far higher.
-
Bending momentMkN·m (kip·ft)
The internal moment at a section of a beam that balances the moments of the external loads on one side of it. A simply supported span under a uniform load w has a maximum of w L²/8 at midspan, and a central point load P gives P L/4. Bending stress is the moment divided by the section modulus.
Beam deflection and bending stress, Steel beam size calculator, Joist span calculator (bending and deflection), Stiffener with attached plating
-
Combination factorψ0dimensionless
Also called psi factor, ψ0
A Eurocode factor that reduces an accompanying variable action in a load combination, because it is unlikely to reach its characteristic value at the same time as the leading action. EN 1990 Table A1.1 gives 0.7 for imposed loads in dwellings and offices, 0.6 for wind and 0.5 for snow at sites up to 1000 m.
-
Dead loadGkkN/m² (psf)
Also called permanent action, permanent load, D
The weight of the permanent parts of a structure: self-weight, fixed finishes, cladding and permanent services. Reinforced concrete weighs about 25 kN/m³, so a 200 mm slab gives 5 kN/m². It is factored by 1.35 in Eurocode and 1.2 in ASCE 7 strength design, and by 0.9 or 1.0 where it resists uplift or overturning.
Load combinations calculator (ASCE 7 LRFD/ASD and Eurocode), Steel beam size calculator, Joist span calculator (bending and deflection)
-
Deflection limitmm (span ratio such as L/360)
Also called L/360, L/240, span/deflection ratio
The maximum deflection allowed for a member, usually stated as a fraction of its span. US practice uses L/360 for live load on floors, L/240 for total load and L/180 for roofs without a ceiling, taking twice the length as the span for cantilevers. Limits protect finishes and comfort rather than strength.
Deflection limits calculator (L/360, L/240), Beam deflection and bending stress, Joist span calculator (bending and deflection), Steel beam size calculator
-
Effective length factorKdimensionless
Also called K factor, buckling length factor, effective length
A multiplier on a column’s actual length that gives the length of an equivalent pin-ended column with the same buckling load. Theoretical values are 1.0 pinned at both ends, 0.7 fixed and pinned, 0.5 fixed at both ends and 2.0 for a cantilever; for design AISC recommends 0.8, 0.65 and 2.1 for the last three.
-
Euler buckling loadPcrkN (kip)
Also called critical buckling load, Euler load, critical load
The axial compressive load at which an ideal straight elastic column becomes unstable and bows sideways: P_cr = π² E I / (K L)². It applies to slender columns only; stockier columns, whose critical stress would exceed about half the yield strength, are checked with the Johnson parabola or code buckling curves.
-
Fillet weld throatamm (in)
Also called throat thickness, effective throat
The effective thickness of a fillet weld, the height of the largest triangle that fits within the weld cross-section, measured from the root. For an equal-leg weld it is 0.707 times the leg length, and weld strength is throat × length × design shear strength. Eurocode practice usually states the throat a, while US drawings give the leg size.
Fillet weld strength, Weld metal and filler consumption calculator
-
Ground snow loadskkN/m² (psf)
Also called characteristic snow load, p_g
The characteristic snow load on level ground at a site, with a 50-year return period in Eurocode and ASCE 7-16. Roof load applies shape, exposure and thermal factors: s = μ1 Ce Ct s_k in EN 1991-1-3, with μ1 = 0.8 up to 30°, and p_f = 0.7 Ce Ct Is p_g for flat roofs in ASCE 7-16.
Snow load calculator (Eurocode and ASCE 7), Load combinations calculator (ASCE 7 LRFD/ASD and Eurocode)
-
Lateral-torsional bucklingnone
Also called LTB
A failure mode of a beam bent about its strong axis in which the compression flange deflects sideways and the section twists, at a moment well below the in-plane capacity. Resistance falls as the unbraced length between lateral restraints grows; a beam whose compression flange is held continuously, for example by a fixed floor deck, does not suffer it.
Steel beam size calculator, Beam deflection and bending stress
-
Live loadQkkN/m² (psf)
Also called imposed load, variable action, L
The load from the occupancy and use of a building: people, furniture, movable partitions and stored goods. Typical characteristic values are 1.5 to 2.0 kN/m² for dwellings and 2.5 to 3.0 kN/m² for offices in EN 1991-1-1, against 40 and 50 psf in ASCE 7. It is factored by 1.5 in Eurocode and 1.6 in ASCE 7 strength design.
Load combinations calculator (ASCE 7 LRFD/ASD and Eurocode), Steel beam size calculator, Joist span calculator (bending and deflection), Deflection limits calculator (L/360, L/240)
-
Load combinationnone
Also called load case, LRFD combination, ASD combination
A set of factored loads added together to check a structure for one design situation, with the most severe result governing. Typical strength combinations are 1.2D + 1.6L + 0.5S in ASCE 7 LRFD and 1.35 G_k + 1.5 Q_k + 1.5 ψ0 W_k in Eurocode expression 6.10. Uplift checks pair 0.9D with full wind.
Load combinations calculator (ASCE 7 LRFD/ASD and Eurocode), Snow load calculator (Eurocode and ASCE 7), Wind load calculator (Eurocode and ASCE 7)
-
Miner’s ruleDdimensionless
Also called Palmgren–Miner rule, cumulative damage, linear damage rule
A linear rule for fatigue under variable amplitude loading that sums, over all stress ranges, the cycles applied divided by the cycles to failure. Failure is predicted when the damage sum reaches 1.0; offshore practice such as DNV-RP-C203 multiplies the damage by a design fatigue factor of 1 to 10 before comparing it with 1. Load sequence effects are ignored.
Weld fatigue damage (DNV-RP-C203), Fatigue safety factor calculator (Goodman, Gerber, Soderberg)
-
Partial factorγdimensionless
Also called partial safety factor, load factor, gamma factor
A factor applied to characteristic loads or material strengths in limit state design to cover uncertainty in each. Eurocode uses γ_G = 1.35 for permanent and γ_Q = 1.5 for variable actions, and γ_M0 = 1.0 for steel cross-section resistance; ASCE 7 load factors of 1.2 and 1.6 play the same role.
Load combinations calculator (ASCE 7 LRFD/ASD and Eurocode), Steel beam size calculator, Soil bearing capacity calculator (Terzaghi and Eurocode 7)
-
Peak velocity pressureqpkN/m² (psf)
Also called velocity pressure, wind pressure, q_z
The dynamic pressure of the wind at height z including gust effects, multiplied by pressure coefficients and area to give wind forces. Eurocode gives q_p = (1 + 7 I_v) × ½ ρ v_m² with ρ = 1.25 kg/m³; ASCE 7-16 gives q_z = 0.613 K_z K_zt K_d K_e V² in Pa, with V in m/s.
-
Rebarkg/m (lb/ft)
Also called reinforcing bar, reinforcement, reinforcing steel
Ribbed steel bar cast into concrete to carry tension and control cracking. Europe commonly uses grade B500, with 500 MPa yield, and the US Grade 60, with 420 MPa; mass per metre is d²/162 kg with d in mm, and US bar numbers up to #8 give the diameter in eighths of an inch.
Rebar weight and quantity calculator, Concrete volume and rebar weight, Concrete slab calculator, Concrete footing calculator
-
Second moment of areaImm⁴ (in⁴)
Also called area moment of inertia, moment of inertia, I value
A cross-section property measuring resistance to bending about an axis, the integral of y² over the area, with y measured from the neutral axis. A rectangle has b h³/12, so doubling its depth makes it eight times stiffer; offset parts add A d² by the parallel axis theorem. Deflection is inversely proportional to E I.
Moment of inertia calculator (section properties), Beam deflection and bending stress, Column buckling (Euler and Johnson), Steel beam size calculator, Joist span calculator (bending and deflection), Stiffener with attached plating
-
Section modulusWelmm³ (in³)
Also called elastic section modulus, plastic section modulus, S, Z
The second moment of area divided by the distance from the neutral axis to the extreme fibre, which gives bending stress as σ = M / W. A rectangle has b h²/6. The plastic modulus W_pl, called Z in US practice, is 1.5 times the elastic value for a rectangle and about 1.10 to 1.15 times for rolled I-sections.
Moment of inertia calculator (section properties), Steel beam size calculator, Beam deflection and bending stress, Joist span calculator (bending and deflection), Stiffener with attached plating
-
Serviceability limit statenone
Also called SLS
A condition beyond which a structure no longer meets its requirements for normal use, such as excessive deflection, vibration or crack width, without any collapse. Checks use characteristic or other unfactored load combinations with partial factors of 1.0, and limits such as span/360 for floor deflection.
Deflection limits calculator (L/360, L/240), Beam deflection and bending stress, Load combinations calculator (ASCE 7 LRFD/ASD and Eurocode), Joist span calculator (bending and deflection)
-
Shear forceVkN (kip)
The internal force acting across a beam section perpendicular to its axis, equal to the sum of the transverse loads on one side of the section. A simply supported beam under a uniform load w has a maximum of w L/2 at each support. Bending moment is greatest where the shear force passes through zero.
Beam deflection and bending stress, Steel beam size calculator, Joist span calculator (bending and deflection)
-
Slenderness ratioKL/rdimensionless
Also called KL/r, slenderness, radius of gyration
The effective length of a compression member divided by its radius of gyration r = √(I/A), a measure of how prone it is to buckling. AISC recommends KL/r of no more than 200 for compression members; for steel with 250 MPa yield the boundary between Johnson and Euler behaviour lies near 126.
Column buckling (Euler and Johnson), Moment of inertia calculator (section properties)
-
Terrain categorynone
Also called exposure category, ground roughness
A classification of ground roughness upwind of a site that sets how wind speed varies with height. EN 1991-1-4 runs from category 0, sea, to IV, where at least 15 % of the area is covered by buildings taller than 15 m; ASCE 7 uses exposures B (urban and suburban), C (open terrain) and D (flat ground and water).
-
Ultimate limit statenone
Also called ULS
A condition associated with collapse or other structural failure, such as rupture, excessive plastic deformation, buckling, loss of equilibrium or fatigue. Checks compare design load effects, from characteristic loads multiplied by partial factors such as 1.35 and 1.5, with design resistances reduced by material factors.
Load combinations calculator (ASCE 7 LRFD/ASD and Eurocode), Steel beam size calculator, Column buckling (Euler and Johnson)
Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person.