Energy and renewables glossary
20 terms from the energy and renewables calculators, each in two or three sentences with its symbol, its unit and a typical value. Every entry links to the calculators that use it; the formula sheet has the equations.
-
Ampere-hourAh (mAh)
Also called Ah, mAh, amp-hour, battery capacity
The charge delivered by a current of one ampere for one hour, 3600 coulombs, used to rate battery capacity at a stated discharge time. Energy in watt-hours is ampere-hours times nominal voltage, so a 100 Ah, 12 V battery holds 1.2 kWh and a 5000 mAh, 3.7 V phone cell 18.5 Wh.
mAh to Wh battery capacity, Battery capacity and runtime, Solar battery bank calculator, Battery charge time
-
Betz limitdimensionless
Also called Betz’s law, 59.3 %
The theoretical maximum share of the kinetic energy in the wind that any open rotor can extract, 16/27 or 59.3 %, derived by Albert Betz from momentum theory. Large modern turbines reach a power coefficient of about 0.45 to 0.50 at their best operating point. A claim above the limit points to a wrong swept area or wind speed.
-
C-rate1/h (multiple of C)
Also called C rate, charge rate, discharge rate
The charge or discharge current of a battery expressed as a multiple of its ampere-hour capacity. For a 100 Ah battery 1C is 100 A and 0.2C is 20 A; lead-acid capacity is usually rated at C/20, while lithium iron phosphate cells accept 0.5C to 1C continuously. Higher rates reduce usable capacity and raise heating.
Battery charge time, Battery capacity and runtime, Solar PV array and storage sizing
-
Capacity factordimensionless (%)
Also called load factor, net capacity factor
The ratio of the energy a plant actually produces over a period to what it would produce running at full rated power the whole time. Onshore wind typically achieves 25 % to 35 %, offshore wind 40 % to 50 %, and solar PV 10 % to 25 %. Annual energy is rating × 8760 h × capacity factor.
Wind turbine power calculator, Solar battery bank calculator
-
Days of autonomydays
Also called autonomy, backup days
The number of days an off-grid battery bank must supply the full daily load with no solar or wind input. Homes with a backup generator are often designed for 2 to 3 days, unattended telecom and remote sites for 5 days or more. Bank capacity in ampere-hours is daily watt-hours × days ÷ (depth of discharge × bank voltage).
Solar PV array and storage sizing, Solar battery bank calculator
-
Depth of discharge%
Also called DoD, DOD
The share of a battery’s rated capacity drawn out before it is recharged. Cycle life falls steeply as it rises, so lead-acid banks are usually designed for 50 % and lithium iron phosphate for 80 % or more. Usable energy is rated capacity × depth of discharge.
Solar battery bank calculator, Battery capacity and runtime, Solar PV array and storage sizing
-
Kilowatt-hourkWh (MJ)
Also called kWh, unit of electricity
The energy delivered by one kilowatt of power for one hour, 3.6 MJ, the unit on electricity bills. A 2 kW heater run for 3 hours uses 6 kWh, which at 0.30 per kWh costs 1.80. Confusing the kW of a rating, a rate, with kWh, an amount, is the most common slip in energy sums.
Electricity cost and energy use, EV charging time and cost calculator, Solar panel calculator: how many panels do I need?, Heat pump vs gas boiler running cost calculator, mAh to Wh battery capacity
-
Levelised cost of energycurrency/kWh
Also called LCOE, levelized cost of electricity
The constant price per kWh at which a generating system’s discounted lifetime revenue would equal its discounted lifetime costs. In words, it is the present value of all costs divided by the present value of all energy produced. It puts solar, wind and grid supply on one basis, and the result depends strongly on the discount rate.
-
Maximum power point trackingnone
Also called MPPT, MPPT controller
A charge controller or inverter function that keeps adjusting a PV array’s operating voltage to the point on its current-voltage curve where power is greatest. It typically harvests 10 % to 30 % more energy than a PWM controller, the gain being largest in cold weather or when array voltage is well above battery voltage.
Solar PV array and storage sizing, Solar battery bank calculator
-
Net headHnm (ft)
Also called effective head, gross head
The head actually available to a hydro turbine: the gross vertical drop from intake water level to the turbine, less friction and fitting losses in the penstock. Penstocks are usually sized so losses stay below about 10 % to 15 % of gross head. Power is ρ × g × flow × net head × overall efficiency.
-
Onboard chargerkW
Also called OBC, Level 2 charging, AC charging
The AC to DC converter built into an electric vehicle that charges its battery from an AC supply such as a wall box. Typical ratings are 7.4 kW single-phase and 11 kW or 22 kW three-phase, and the car charges at the lower of its own rating and the wall box power. DC fast chargers bypass it.
-
Open-circuit voltageVocV
Also called Voc
The voltage across a solar module’s terminals with no current flowing, the highest voltage it produces. It rises as the cells get colder, about 0.3 % per kelvin for crystalline silicon, so strings are sized at the lowest site temperature to stay under the inverter or charge controller maximum input voltage.
-
Peak sun hoursh/day (kWh/m²/day)
Also called PSH, sun hours, insolation
The daily solar energy on the array plane expressed as hours of sunshine at 1000 W/m², numerically equal to kWh/m² per day. Southern Europe sees about 6 to 7 in summer and 2 to 3 in winter, northern Europe 1 or less in December. Array power needed is daily energy ÷ (peak sun hours × system efficiency).
Solar panel calculator: how many panels do I need?, Solar PV array and storage sizing, Solar battery bank calculator
-
Peukert’s lawkdimensionless
Also called Peukert exponent, Peukert effect
An empirical rule that a battery’s available capacity falls as discharge current rises: runtime t = H × (C ÷ (I × H))^k, where H is the rated discharge time. The exponent k is about 1.1 to 1.3 for lead-acid and close to 1.03 for lithium iron phosphate. It matters most for lead-acid banks discharged fast.
Battery capacity and runtime, Solar battery bank calculator, Solar PV array and storage sizing
-
Power coefficientCpdimensionless
Also called Cp, rotor efficiency
The fraction of the wind’s kinetic power through the swept area that a turbine converts, so P = ½ × ρ × A × v³ × C_p. Its ceiling is the Betz limit of 0.593; large three-blade turbines reach about 0.45 to 0.50 aerodynamically, and small turbines about 0.25 to 0.35 from wind to electricity.
-
Round-trip efficiency%
Also called RTE, storage efficiency, charge efficiency
The share of the energy put into storage that comes back out, measured AC to AC or DC to DC. Lithium-ion batteries typically return 85 % to 95 %, lead-acid 70 % to 85 % and pumped hydro 70 % to 80 %. The losses mean a solar array must produce more energy than the load uses.
Solar PV array and storage sizing, Battery capacity and runtime, Battery charge time, EV charging time and cost calculator
-
Seasonal coefficient of performancedimensionless
Also called SCOP, SPF, seasonal performance factor
The heat a heat pump delivers over a whole heating season divided by the electricity it uses, including defrost and part-load running. Air-source units typically achieve 2.5 to 4 and ground-source 3.5 to 5. A heat pump costs less to run than a gas boiler when it exceeds boiler efficiency × electricity price ÷ gas price.
Heat pump vs gas boiler running cost calculator, Water heating time calculator (tank, element, gas or heat pump), Carnot efficiency and COP calculator
-
Simple payback periodyears
Also called payback period, payback time
The time for an investment’s savings to repay its net cost: net cost divided by first-year saving, ignoring price changes, degradation and the time value of money. Home solar systems in sunny regions often pay back in 6 to 10 years. It is easy to explain but favours quick returns over better long-term projects.
Solar panel payback calculator, Energy-saving device payback
-
Standard test conditionsnone
Also called STC, Wp, watt-peak
The reference conditions at which solar module ratings are measured: irradiance 1000 W/m², cell temperature 25 °C and air mass 1.5 spectrum, per IEC 60904. Cells in full sun run 20 K to 30 K above ambient, so on a warm day output is often 10 % to 15 % below the STC rating.
Solar PV array and storage sizing, Solar panel calculator: how many panels do I need?, Solar panel payback calculator
-
State of charge%
Also called SoC, SOC, battery level
The charge remaining in a battery as a percentage of its full capacity, the fuel gauge of an electric vehicle or storage system. EV fast charging slows sharply above about 80 %, so trips are planned from roughly 10 % to 80 %. Lead-acid charge can be read from rest voltage; flat-curve lithium iron phosphate needs current counting.
EV charging time and cost calculator, Battery charge time, Battery capacity and runtime