Blending ratio calculator (two liquids to a target property)

Fractions and volumes of two liquids to blend to a target concentration, density, sulphur content or viscosity (Refutas), by mass or by volume.

Units

Results are estimates. They do not replace the governing code, class or flag requirements, or a check by a competent person. Report a problem

Introduction

How much of each liquid do you need to reach a target? For a property that blends linearly, the fraction of liquid A is (target − B) / (A − B). Sulphur and concentration in % w/w blend by mass. Density and % v/v blend by volume. Viscosity does not blend linearly at all. It is first turned into a blending number, such as the Refutas index, which does blend by mass. Blending ISO VG 100 and VG 32 oils to VG 68 takes 69 % of the VG 100 by mass, not the 53 % a straight line between 32 and 100 suggests.

This calculator gives the mass and volume fractions of two liquids that reach a target, and the volume and mass of each for a batch. It handles mass-linear properties, volume-linear properties and kinematic viscosity by the Refutas method. It is for process, fuel and lubricant engineers, and for anyone mixing two stocks to a specification.

Formulas

Fraction of liquid A for a linear property, on its blending basis:

f_A = (P_target − P_B) / (P_A − P_B)

Refutas viscosity blending number, blended by mass fraction:

VBN = 14.534 × ln(ln(ν + 0.8)) + 10.975
w_A = (VBN_target − VBN_B) / (VBN_A − VBN_B)
ν = exp(exp((VBN − 10.975) / 14.534)) − 0.8

Mass and volume fractions, with additive volumes:

φ_A = (w_A / ρ_A) / (w_A / ρ_A + w_B / ρ_B)
ρ_blend = φ_A ρ_A + φ_B ρ_B
  • P — property value; f_A — fraction of A by mass or by volume
  • ν — kinematic viscosity in cSt, all at the same temperature
  • w — mass fraction; φ — volume fraction; ρ — density

Assumptions and limitations

  • Choose the basis that matches the property. Sulphur, ash and concentration in % w/w blend by mass. Density and % v/v blend by volume.
  • Both viscosities and the target must be at the same temperature. The Refutas method is accurate to a few per cent for miscible petroleum oils.
  • Volumes are taken as additive. Alcohol and water shrink by up to about 4 % on mixing, so the batch comes out short.
  • The calculator does not check compatibility. Some residual and distillate fuels form sludge when mixed, so test before blending different fuel types.

Worked example

A workshop has ISO VG 100 and ISO VG 32 hydraulic oil, of densities 880 and 860 kg/m³, and wants 1 000 L of VG 68. All viscosities are at 40 °C.

  1. Blending numbers: VBN(100 cSt) = 33.196, VBN(32 cSt) = 29.143, VBN(68 cSt) = 31.940.
  2. Mass fraction of VG 100: (31.940 − 29.143) / (33.196 − 29.143) = 69.0 %.
  3. Volume fraction of VG 100: (0.690 / 880) / (0.690 / 880 + 0.310 / 860) = 68.5 %.
  4. Quantities: 685 L of VG 100 and 315 L of VG 32.

A straight-line mix by viscosity would have used only about 530 L of VG 100 and given an oil of about 57 cSt.

FAQ

How do I calculate a blending ratio?

For a linear property, the fraction of A is (target − B) / (A − B). To blend 3.5 % and 0.1 % sulphur fuels to 0.5 %, use 0.4 / 3.4 = 11.8 % of the high-sulphur fuel by mass.

Why can't I average viscosities?

Viscosity changes roughly exponentially with composition, so a thin oil lowers the blend's viscosity far more than a straight line predicts. A 50/50 mass blend of 10 and 100 cSt oils is about 26.7 cSt.

What is the Refutas method?

A viscosity blending index developed at Shell: VBN = 14.534 ln(ln(ν + 0.8)) + 10.975. The VBN of a blend is the mass-weighted mean of the components' VBN.

Should I blend by mass or by volume?

Blend by the basis the property is defined on. Sulphur in % m/m blends by mass. Density blends by volume. The calculator converts between the two with the densities.

Does density blend linearly?

By volume, yes, if the volumes add. A 30.5 % by volume blend of 991 and 860 kg/m³ fuels has a density of 900 kg/m³.

Can I blend more than two components?

Not on this page. With three or more, the target fixes only one equation, so you must choose the other ratios first.

Related calculators

What this calculator is checked against

Before every release the calculator must reproduce each case below. The note under each case says where the expected answer comes from: a standard, a textbook, a published table, or a hand calculation shown in full.

  1. ISO VG 100 and VG 32 to VG 68: VBN 33.196, 29.143 and 31.940; 69.0 % VG 100 by mass, 68.5 % by volume, 685 L of 1 000 LRefutas VBN = 14.534 ln(ln(ν + 0.8)) + 10.975 (Maples; ASTM D7152 family), hand calculation; ISO 3448 grade midpoints
  2. Refutas: VBN(10 cSt) = 23.57 and VBN(100 cSt) = 33.20; a 50/50 mass blend is 26.7 cSt, not the 55 cSt averageRefutas method as verified in the fuel-blend-heating calculator (VBI 23.58 and 33.20, blend 26.7 cSt)
  3. Sulphur by mass: 3.5 % and 0.1 % fuels blend to 0.5 % S at 11.76 % of the high-sulphur fuel by mass, 10.37 % by volume (991 and 860 kg/m³)Linear blending by mass (Maples), hand calculation: w = (0.5 − 0.1) / (3.5 − 0.1)
  4. Density by volume: 991 and 860 kg/m³ blend to 900 kg/m³ at 30.53 % by volume; the blend density is the targetLinear blending by volume with additive volumes, hand calculation: φ = 40 / 131
  5. Limits: a target equal to A gives 100 % A; VBN inverts exactly; a target outside A and B and equal properties are rejectedBehaviour check: warnings and rejected inputs
  6. Worked example of the article: the calculator reproduces 33.196, 29.143, 31.940, 69.0 %, 68.5 %, 685 L, 315 L to the digits printedThe worked example on this page, to the digits printed

Assumptions and sources

Assumptions and limits

  • Mass-based properties (concentration in % w/w, sulphur in % m/m, ash, water by mass) blend linearly by mass fraction; volume-based properties (density, % v/v, often the octane number as an approximation) blend linearly by volume fraction.
  • Viscosity blends by the Refutas method: the viscosity blending number VBN = 14.534 ln(ln(ν + 0.8)) + 10.975 is linear in mass fraction, with both viscosities at the same temperature; it is accurate to a few per cent for miscible petroleum oils.
  • Volumes are taken as additive (no shrinkage on mixing), which is close for similar hydrocarbons but not for alcohol and water, whose mix shrinks by up to about 4 %.
  • Compatibility and stability are not predicted: some residual and distillate fuels precipitate asphaltenes when blended; test before blending fuels of different types.

Sources

  • ASTM D7152, Standard Practice for Calculating Viscosity of a Blend of Petroleum Products (blending-index methods)
  • Maples, R.E., Petroleum Refinery Process Economics, 2nd ed., PennWell, 2000 (Refutas viscosity blending index; linear blending of sulphur by weight and gravity by volume)
  • ISO 3448:1992 Industrial liquid lubricants — ISO viscosity classification (VG 32, 68, 100 midpoints at 40 °C)

Cite this calculator

Papandreou, C. (2026). Blending ratio calculator (two liquids to a target property). Engineering Bible. https://engineeringbible.com/process/blending-ratio/

Embed this calculator on your site

Copy this HTML into your page. The calculator stays free to use and links back here.

By Christos Papandreou. Updated . How the numbers are checked.